Intelligent Voltage Transformer Calibrator

Send Inquiry
Intelligent Voltage Transformer Calibrator
Details
The MOEORW-W8011 intelligent voltage transformer field calibrator is a professional voltage transformer field tester in the field of high voltage electrical testing, with precise positioning to meet the essential needs of on-site verification.
Category
CT PT Analyzer
Share to
Description

MOEORW-W8011 Intelligent Voltage Transformer Calibrator

The MOEORW-W8011 intelligent voltage transformer field calibrator is a professional voltage transformer field tester in the field of high voltage electrical testing, with precise positioning to meet the essential needs of on-site verification.

It integrates multiple testing methods, eliminating the need for multiple devices, intelligently identifies errors with accurate data, and is easy and efficient to operate.

Suitable for on-site verification of high-voltage power metering devices in power plants, substations and various users.

 

Product Introduction

 

High-voltage power metering devices in power plants and substations, as well as power metering devices for numerous users, affect the interests of multiple parties, including power generation, transmission, supply, and users. To ensure accurate metering, inspections must be conducted in accordance with JJG1021-2007 "Power Transformers" and DL/T448-2000 "Technical Management Regulations for Power Metering Devices".

Our MOEORW-W8011 low-caliber high-voltage transformer field tester is developed using advanced testing technology, large-scale electronic circuit design, and in accordance with relevant national regulations. It solves the problems of high workload and cumbersome operation in on-site voltage transformer verification, while also offering reliable performance and powerful functionality.

 

Product Parameter (specification)

 

1: Error Measurement Section for Low-Voltage High-Voltage Transformers

① Overall accuracy: 1/3 of the error limit of the voltage transformer under test

②Test range:

product-504-211

③ Operating range of the voltage transformer under test: 80%~120%

④ Secondary load: 0.0VA~300VA , COSφ=0.1~1.0

⑤ Accuracy range of the voltage transformer under test: 1.0, 0.5, 0.2, 0.1

⑥ Resistance and admittance measurement error ≤ 5.0%

Measurement range: R : 0.00Ω~5.0Ω

Y: 0.000mS~200.0mS

2: Voltage Transformer Calibrator Section

①Basic error:

In-phase component: DX = ±( X × 2% + Y × 2% ±(2 words))

DY = ±( X × 2% + Y × 2% ±5 characters)

" X ", " Y " - the instrument's displayed values

Five words – Instrument quantization error

Dial scale: Level 1 .

Measurement range: f: 0.0000%~200.0%

δ: 0.000′~999.9′

② Rated operating voltage: 100/3V , 100/ product-23-27V, 100V

③ Operating range of the voltage transformer under test: 20%~200%

3. Instrument power consumption: 20 VA

4. Instrument accuracy class: 0.05

5. Maximum external dimensions ( cm ): L46 ´W35 ´H13.5

6: Weight ( kg ) : 11.0

 

Product features and applications

 

1. The MOEORW-W8011 low-calibration high-voltage transformer field tester combines the functions of measuring voltage transformer error using both the low-calibration high-voltage method and the potential difference method, making it convenient for on-site calibration of metering devices.

2. On-site verification of voltage transformers does not require standard voltage transformers, step-up transformers, load boxes, and voltage regulation control boxes. The verification of electromagnetic voltage transformers can be carried out using extremely simple test wiring and operation, which greatly reduces the workload and improves the work efficiency, making it convenient to carry out on-site verification of transformers.

3. The MOEORW-W8011 low-voltage transformer field tester contains a standard voltage transformer with the same transformation ratio as the voltage transformer under test, with an accuracy of 0.02 class. It accurately measures the transformation ratio and no-load error of the voltage transformer under test. Then, it calculates the transformer error by combining the impedance and admittance test results.

4. Wide measurement range, up to 6 kV/100V~220kV / V product-26-36/ 100 / V product-26-36.

5. It has the function of testing voltage transformer ratio, DC internal resistance and voltage load box.

6. It has a dual-winding voltage transformer testing function and two load boxes.

7. It adopts a 640×480 high-resolution large-screen LCD display with a user-friendly interface and operation design. The touch screen assists in operation, making operation more convenient and faster.

8. By employing precise software algorithms, the accuracy of measurement data is further improved.

9. It has the ability to intelligently judge the status of external wiring and prompt for wiring errors, turns ratio errors, polarity errors, etc.

10. Automatically round the test data and determine whether it exceeds the tolerance. Data exceeding the tolerance is highlighted in black, making the data characteristics of the current transformer intuitive and clear.

11. Issue the on-site inspection conclusion directly, indicating whether it is qualified or unqualified.

12. Large-scale memory can store up to 1,000 field test data entries.

13. Equipped with a printer, it can print test data on-site.

14. The engineering plastic mold chassis is used for shock and pressure protection, ensuring the safety of operators and equipment during high-pressure testing on site.

 

Prodection details

 

Verification of high-voltage power metering devices in power plants/substations

It is used for on-site error verification, ratio testing, resistance and admittance detection of high-voltage voltage transformers in power plants and substations, ensuring the accuracy of high-voltage power metering and complying with the relevant requirements of JJG1021-2007 and DL/T448-2000.

Testing of various types of user electricity metering devices

On-site verification of voltage transformers at various power users' terminals is carried out to complete tests on indicators such as transformer no-load/load error, secondary load, and DC internal resistance, solving the problems of cumbersome on-site verification operations and complicated equipment.

On-site testing of all parameters of voltage transformers

It is suitable for verifying the transformation ratio and polarity of electromagnetic voltage transformers, measuring excitation admittance and primary winding impedance, as well as synchronous testing of multiple windings of dual-winding voltage transformers, meeting the needs of full parameter testing of transformers on site.

Traditional potential difference method verification scenarios

It can be used with standard voltage transformers, step-up transformers, load banks and other equipment to carry out the traditional potential difference method error verification of voltage transformers, and is compatible with the traditional verification operation mode in the laboratory and on the field.

 

Company Qualifications

 

 

FAQ

Q: Are you a factory or a trading company?

We are a professional manufacturer of testing equipment.

Q: How is the after-sales service?

A: The warranty period is 12 months. After the warranty period, we also provide lifetime service paidrepair or service.

Q: How is the after-sales service?

A: The warranty period is 12 months. After the warranty period, we also provide lifetime service paidrepair or service.

Q: What about transportation?

A: It depends on your requirements. We can ship to your airport by air, to your seaport by sea, or to your office by courier.
We also accept cooperation with your shipping agent.

Q: Are your keyboard, interface, software, and manuals in English?

A: Yes, if you are using the English version of the keyboard, interface, software, and manual and require other languages, please contact us for confirmation.

 

Hot Tags: intelligent voltage transformer calibrator, China intelligent voltage transformer calibrator manufacturers, factory, ct pt analyzer, Fully Automatic Transformer Calibration Bench, Transformer Field Calibrator