Product Introduction
MOEORW-W105W2 Trace Moisture Tester, also named Karl Fischer Moisture Analyzer, Coulombic Water Content Detector, Insulating Oil Micro-water Tester, Oil Trace Moisture Analyzer, Laboratory Coulometric Titrator, is a self-developed fully automatic coulometric titration trace moisture testing equipment. Adopting the industry-standard Karl Fischer coulometric titration method, it provides accurate trace moisture testing solutions for solid, liquid and gas samples for power, petrochemical, pharmaceutical, environmental protection and third-party testing laboratories.
Equipped with a 64K high-definition color touch LCD screen and high-performance ARM processor, the machine features fast testing response and strong anti-interference performance. It comes with 5 core standard functions: real-time dynamic potential curve display, storage of 1000 test records, customizable delayed titration and automatic thermal printing. It supports single-unit purchase for individual laboratories and small factories, as well as mass procurement and multi-station simultaneous deployment for large oil refineries, power grid maintenance companies and testing institutions.
Each MOEORW-W105W2 Insulating Oil Micro-water Tester undergoes 72-hour continuous power aging test and double calibration with standard pure water before delivery. Its testing error fully complies with official technical standards. Test results can be directly applied to quality inspection records, third-party metering acceptance and project bidding without recognition risks from clients. A single unit supports moisture testing of full-range samples including insulating oil, chemical solvents, pharmaceutical raw materials, liquid oil products, solid powder and industrial gas. Factories do not need to stock multiple models for mass procurement, which greatly cuts comprehensive costs of instrument purchasing, warehousing and management.
Product Parameter (specification)
|
Parameter Item |
Official Calibrated Value |
Wholesale Advantage & Credibility Evidence |
|
Titration Mode |
Coulometric Titration (Karl Fischer Coulometry) |
Official standard testing method for power and petrochemical industries, recognized by all metering institutes and bidding projects. Reports generated by MOEORW-W105W2 Karl Fischer Moisture Analyzer are fully compliant. |
|
Testing Range |
0μg~200mg, optimal range:10μg~100μg |
Covers all trace moisture testing scenarios of oil and reagents. One Oil Trace Moisture Analyzer fits all factory samples; no need to purchase separate models for bulk orders. |
|
Sensitivity Threshold |
0.1μg |
Ordinary moisture testers only reach 1μg sensitivity. This Laboratory Coulometric Titrator captures ppm-level ultra-trace moisture without missed detection, a mandatory purchasing standard for power grids and large chemical plants. |
|
Testing Accuracy |
3μg-1000μg: ≤±3μg; ≥1000μg: ≤±0.2% |
Quantified error data can be directly added to enterprise quality inspection SOP. Stable parallel test results for mass samples, meeting CNAS laboratory standards. |
|
Electrolysis Current |
0-400mA, self-adaptive, max.300mA |
Automatically adjusts electrolysis speed based on sample moisture content. No baseline drift during 8-hour continuous mass testing in workshops, less downtime for calibration. |
|
Data Storage Capacity |
1000 test records |
Records stored for 10 years after power failure when multiple Coulombic Water Content Detectors run simultaneously, easy for safety supervision and quality record tracing. |
|
Operation Display |
64K color touch screen, sliding stepless stirring speed control |
Unified standard 4-speed stirring. Consistent testing conditions across all bulk-purchased units, comparable data; new operators get qualified after simple training. |
|
Output Accessory |
56mm mini thermal printer, automatic result printout |
Printer built-in as standard, no extra peripheral purchase needed. Instant paper test reports for compliant factory filing. |
|
Power Supply |
AC220V±10%, 50Hz±2%, total power ≤35W |
Multiple units running together do not overload workshop circuits. Low power consumption cuts long-term electricity cost and factory operation expense. |
|
Working Environment |
Temp:10~40℃, Humidity ≤85%RH |
Applicable to workshops, outdoor substations and common labs; no special constant temperature & humidity room required, flexible mass layout. |
|
Overall Dimension |
350mm * 260mm * 180mm (L×W×H) |
Compact footprint saves workstation space. Multiple units can be placed side by side for multi-station quality inspection labs. |
Product feature
1.Ultra-high Precision Testing Advantages
- Standard Karl Fischer reaction system with separated dual electrodes MOEORW-W105W2 Trace Moisture Tester adopts independent measuring electrode and electrolytic electrode, separated cathode and anode chambers to isolate electrolytic interference. Blank current remains stable during continuous mass sample testing without frequent unbalance shutdown. The range of 6 parallel tests for identical samples ≤2μg, far better repeatability than ordinary industrial insulating oil micro-water testing equipment.
- 0.1μg ultra-high sensitivity for ultra-low moisture samples Most insulating oil and high-purity chemical reagents only contain dozens of micrograms of water, which easily cause data distortion on common testers. This Karl Fischer Moisture Analyzer detects minimum 0.1μg water and accurately distinguishes tiny ppm-level moisture differences, a must-have device for mass procurement of power enterprises and fine chemical plants.
- ARM intelligent chip for automatic electrolysis current adjustment Real-time electrolysis power adjustment based on sample water content enables fast titration for high-moisture samples and prevents over-titration for low-moisture samples. It boosts mass oil testing efficiency by 40% and reduces reagent consumption effectively.
2.Fully Intelligent & User-friendly Operation
- 5 built-in calculation formulas; parameters editable in real time without interrupting titration MOEORW-W105W2 Coulombic Water Content Detector embeds 5 sets of calculation formulas F1-F5, covering volume sampling, weight sampling, tare-weight samples, diluted samples and direct microgram reading, matching all testing standards of liquid oil, solid powder and diluted reagents. Oil refineries and pharmaceutical factories only need one unit for multi-category samples, cutting inventory SKUs for bulk procurement. Formula Details: F1=DT/(V*SG) ppm (liquid oil calculation by volume & specific gravity) F2=DT/(W-w) ppm (solid sample with tare weight) F3=DT/W′ ppm (direct weighed sample) F4=DT/(W/K) ppm (diluted sample) F5=DT ug (direct measured moisture microgram value)
- Visual dynamic potential curve + automatic fault diagnosis Real-time titration potential curve displayed on screen, allowing operators to directly identify failed electrolyte, contaminated electrodes and endpoint unbalance. Pop-up fault alerts for multiple running Laboratory Coulometric Titrators drastically cut manual inspection workload and avoid mass sample waste during testing.
- Custom delayed titration function for ultra-low moisture samples Adjustable titration delay in seconds. Electrolysis current activates with delay after clicking "Start" to eliminate interference from ambient trace moisture, greatly improving data stability for mass low-moisture insulating oil testing.
- Sliding touch stepless stirring speed control to prevent reagent splashing Factory-recommended standard 4-speed stirring with left/right sliding adjustment. Uniform stirring speed across all bulk-purchased units standardizes testing conditions; new operators can work independently without complicated training.
3.Low Maintenance & Long Service Life
- Detachable split titration cell with replaceable individual parts for lower maintenance cost Modular design for titration cell, drying tubes, measuring electrode and electrolytic electrode. No full-unit factory return required if single component breaks. Bulk clients can stock consumables in batches, cutting single-part maintenance cost by 60%. Ground joints sealed with vacuum grease for weekly simple maintenance and long-term stable sealing.
- Dual drying tube color-changing silica gel moisture-proof system extends electrolyte service cycle MOEORW-W105W2 Oil Trace Moisture Analyzer is equipped with cathode and anode dual drying tubes. Blue silica gel absorbs ambient moisture to prevent air water entering the cell. Only silica gel needs replacement when it turns pale blue, extending electrolyte replacement interval by 30% and reducing long-term factory consumable expenditure.
- Ultra-low power consumption + 10-year power-off time & data storage Total power ≤35W for low electricity cost when multiple units standby 24h in workshops. System time and test records remain stored for 10 years after power loss, meeting factory long-term quality record tracing and safety inspection requirements.
Product Application
Single-unit purchase for small lube factories, university labs and mini pharmaceutical workshops for testing small batches of oil, reagents and raw materials. Easy operation with full set of consumables delivered together for immediate use after receipt.
- Power Industry: Power grid substations and power maintenance companies purchase bulk MOEORW-W105W2 Insulating Oil Micro-water Testers for mass trace moisture testing of transformer insulating oil; multiple units process regional inspection samples simultaneously.
- Petrochemical Industry: Oil refineries and fine chemical workshops adopt Oil Trace Moisture Analyzers for continuous sampling and quality control of pipeline raw materials and finished oil products.
- Third-party Testing Institutions: Labs deploy bulk Coulombic Water Content Detectors on multi-stations to process customer water, oil and solid samples in parallel and raise daily sample throughput.
- Pharmaceutical Industry: Pharmaceutical quality control labs equip Karl Fischer Moisture Analyzers to test trace moisture of pharmaceutical intermediates and organic solvents in compliance with pharmacopoeia standards.
- Environmental Protection, Railway & Research Institutes: Mass equipment applied in scientific experiments, environmental gas testing and daily quality inspection of locomotive lubricants.
Product Application
- Titration cell cleaning, drying & assembly: Dry glass parts at 80℃; clean and blow-dry electrodes with methanol/acetone, place stir bar inside, evenly coat ground joints with vacuum grease for sealing.
- Electrolyte filling: Inject 100-120ml Karl Fischer reagent into anode chamber, keep liquid level consistent between anode and cathode chambers, install drying tubes.
- Electrolyte balancing & stabilization: Turn on power for automatic stirring and electrolysis. If "excess iodine" alert pops up, inject a small amount of pure water until potential curve levels near zero.
- Calibration with pure water: Inject 0.1μL standard pure water for calibration. Valid result range:100±3μg. Repeat 2-3 times until error meets standard before sample testing.
- Sample testing: Select matching calculation formula, click Start and inject test sample for automatic titration. Buzzer alerts upon completion with automatic printout of test results.
- Data viewing & storage: Enter setting menu to access 1000 historical test records; one-click clear of all records available.
FAQ
Q: Are you a manufacturer or a trading company?
A: We are a direct manufacturer specializing in high-voltage testing equipment. We have our own R&D team and production facility, which allows us to offer factory-direct pricing and strict quality control.
Q: What is your warranty and after-sales policy?
A: All units come with a 12-month warranty. After the warranty expires, we provide lifetime technical support and paid maintenance services.
Q: Do you support English language interfaces?
A: Yes, our standard models feature English keyboards, software, and user manuals. If you require other languages, please contact us to check availability for customization.
Hot Tags: insulating oil micro-water tester, China insulating oil micro-water tester manufacturers, factory, Automatic Oleic Acid Tester, Freezing Points Tester, Liquid Chromatograph for Furfural Content in Transformer Oil, Oil Filtration Machine, Pour Points Tester, Transformer Oil Moisture Tester