Product Introduction

 

The MOEORW-WXB61-108kVA/54kV Variable Frequency Series Resonant Test System is a heavy-duty AC Hipot solution designed for utility construction and substation commissioning, balancing field wiring simplicity with operator safety to accelerate high-voltage testing. 

 

Product Parameter (specification)

 

  1. Rated capacity:108kVA
  2. Rated output voltage:54kV
  3. Rated voltage: 22kV/52kV/42kV
  4. Output current: 0~15A
  5. Waveform: Pure sine wave
  6. Measurement accuracy: 1.5%

 

Core Advantages & Benefits

 

Exceptional Power Supply Adaptation: Features a highly flexible dual-power input design (220V/380V), ensuring consistently stable performance and uninterrupted operation even under fluctuating grid conditions at remote or harsh field testing sites.

Error-Free Wiring & Asset Protection: Engineered with a heavily simplified physical structure and built-in mistake-proofing mechanisms, minimizing human error during setup and completely eliminating the risk of damage to expensive cables or substation equipment.

Optimized Efficiency for Utility Testing: Tailored perfectly for daily high-voltage construction, providing fully automatic, semi-automatic, and manual testing modes that drastically accelerate routine AC withstand testing on 10kV/35kV power cables, switchgears, and transformers.

Continuous Heavy-Duty Reliability: Equipped with an upgraded industrial thermal management system, supporting extended duration testing under high-voltage, high-current outputs to easily meet demanding project deadlines without overheating.

 

Product Applications

 

108kVA/54kV Variable Frequency Series Resonant Test System

XLPE Power Cable Commissioning: Ideally configured for the field AC withstand voltage testing (AC Hipot) of 10kV and 35kV Cross-Linked Polyethylene (XLPE) insulated power cables, ensuring insulation integrity before final energization or during routine grid maintenance.

Medium-Voltage Switchgear Acceptance: Engineered to deliver precise power-frequency voltage tests for 10kV switchgears, vacuum circuit breakers, and gas-insulated switchgears (GIS) to detect any dielectric defects after transportation or long-term storage.

Substation Instrument Transformers: Highly applicable for the routine voltage withstand and insulation testing of 10kV current transformers (CT) and potential transformers (PT) within substation environments.

Main Transformer Testing Backup: Perfectly capable of performing partial AC withstand and diagnostic hipot testing on main power transformer accessories and lower-voltage winding bars.


 

 

 

What's Included in the Complete Test Set?

 

 

Variable Frequency Power Source (Inverter)

Excitation Transformer

High-Voltage Resonant Reactors

Capacitive Voltage Divider

All Necessary Connecting Cables and Grounding Wires

Factory Test Report & Operation Manual

 

Built to Rigorous International Standard

 

Our system strictly complies with global high-voltage test engineering specifications, including:

IEC 60060: High-voltage test techniques.

IEC 62271: High-voltage switchgear and controlgear.

IEEE 400: Guide for field testing and evaluation of the insulation of shielded power cable systems.

 

Field Testing Safety & Best Practices

 

Essential Safety Tips for Field AC Hipot Testing

  • Proper Grounding First: Ensure the test set and the test object are grounded to a common heavy-duty substation ground grid.
  • Clear Discharge Zone: Always allow sufficient discharging time and use a grounding rod before touching the tested cables.
  • Frequency Tuning Precision: Utilize our automatic tuning mode to quickly find the ideal resonant frequency, reducing stress on the generator.

 

Global Support & After-Sales Warranty

 

Your Reliable Partner in High-Voltage Testing

  • 12-Month Global Warranty: Full warranty covers all system components against manufacturing defects.
  • Lifetime Technical Support: Direct access to senior electrical engineers for remote setup guidance and troubleshooting.
  • Substation-Ready Packing: Housed in rugged, heavy-duty flight cases tailored for rough international transit and demanding field environments.

 

FAQ

 

Q: What is the primary application of this 108kVA 54kV series resonant test system in grid utilities?

A: This series resonant test system is primarily engineered for the field AC withstand testing and AC hipot testing of 10kV and 35kV XLPE power cables, medium-voltage switchgears, circuit breakers, and instrument transformers during substation commissioning.

Q: Can this variable frequency series resonant system operate reliably on portable field generators?

A: Yes. This variable frequency series resonant system features a flexible dual-power input design (220V/380V) with advanced automatic voltage regulation (AVR), allowing the resonant test set to filtering grid harmonics and handle unstable voltage outputs from standard field generators at remote job sites.

Q: What export documentation is provided with the high voltage resonant test set for customs clearance and grid approvals?

A: Each high voltage resonant test set is dispatched with a comprehensive, English-language documentation package. We provide a factory calibration report, routine test certificate, quality inspection certificate, and an in-depth operation manual to satisfy local grid authorities and customs compliance.

Q: How is the heavy AC withstand test equipment protected against rough handling during international shipping?

A: To safeguard this industrial-grade AC withstand test equipment, all core components-including the frequency power source and reactors-are secured in shock-absorbing flight cases, which are then packed inside export-standard, IPPC-compliant fumigated wooden crates to prevent moisture and drop damage during sea or air transit.

Q: Can the resonant reactors of this AC hipot test set be reconfigured for different cable insulation testing requirements?

A: Absolutely. The modular resonant reactors of this AC hipot test set can be connected in series or parallel. This flexibility allows your team to perfectly adjust the inductance and voltage to match the capacitance of various cable insulation testing projects, whether testing short utility lines or long-distance power grids.

 

 

 

Hot Tags: 108kVA 54kV AC Resonant Test System for 10kV/35kV Cable & Switchgear, China 108kVA 54kV AC Resonant Test System for 10kV/35kV Cable & Switchgear manufacturers, factory, 108kVA 108kV Series Resonance Test Device, Series Resonant Test Set, high voltage test system, Hv Resonant Test System, 54kVA 54kV Series Resonance Test Device, Lightweight Variable Frequency Resonant Systems

Send Inquiry