Transformer Loss Parameter Comprehensive Tester

Send Inquiry
Transformer Loss Parameter Comprehensive Tester
Details
MEBT-W4300T1 Transformer Loss Parameter Comprehensive Tester Achieves internationally advanced levels in low power factor measurement. Features proprietary automatic data lock technology. Multi-channel design supports three-phase testing. Automatic range switching. Touchscreen operation for ease of use. Delivers precise detection across multiple scenarios including transformers and motors.
Category
Transformer Load And No Load Loss Tester
Share to
Description

Transformer Loss Parameter Comprehensive Tester

 

Product Introduction

 

The MEBT-W4300T1 Comprehensive Transformer Loss Parameter Tester is a high-tech product featuring precision measurement capabilities at low power factors and proprietary automatic data lock technology. It measures multiple parameters including no-load losses and load losses, supports three-phase power testing and harmonic analysis, and features an 8.0-inch color touchscreen for intuitive operation. Data storage, USB export, and printing capabilities make it widely applicable for testing requirements in transformer, motor, fan, and related industries.

 

Product Parameter (specification)

 

1. Voltage measurement range

AC 10~1000V

2. Current measurement range

AC 0.1~50A

3. Measurement accuracy

Voltage:0.1% ± 0.005V (frequency 40~70Hz)

0.5% ± 0.005V (frequency 70~200Hz)

Current:0.1% ± 0.0002A (frequency 40~70Hz)

0.5% ± 0.0002A (frequency 70~200Hz)

Power:P × 0.1% ± (U × I × 0.02%) ± 0.05W (P is power reading, U is voltage RMS reading, I is current RMS reading)

4. Operating Power Supply

AC 220V ±10%, 50/60 Hz

5. Operating Temperature

-20°C to 40°C

6. Relative Humidity

≤80% RH, no condensation

7. Dimensions

360 × 360 × 200 mm

8. Weight

12 kg

 

Product feature and application

 

1. Measures transformer parameters including no-load loss, load loss, voltage RMS average, current RMS, impedance voltage, zero-sequence impedance, power factor, harmonics, and frequency.

2. Features three voltage test channels and three independent current test channels to support three-phase power testing.

3. Capable of power measurement for low-power-factor test specimens such as amorphous alloy and large power transformers.

4. Automatically captures and precisely locks test data.

5. Compared to similar foreign instruments, it automatically switches ranges across the entire current test range without requiring current measurement module replacement.

6. Input transformer parameters to simultaneously display converted data.

7. Also suitable for power measurement of motors, fans, and similar equipment.

8. Capable of voltage and current measurement for 150Hz and 200Hz induced withstand voltage tests.

9. Harmonic analysis capability.

10. 8.0-inch color LCD display with intelligent touch technology for intuitive operation.

11. Features data storage, USB export, data printing, and computer control functions.

 

Prodection details

 

Suitable for the power, motor, and fan industries, it can measure parameters such as no-load/load losses, zero-sequence impedance, and harmonics for equipment like transformers and motors. It also meets voltage and current detection requirements for 150Hz/200Hz induced withstand voltage tests and accommodates testing needs for low power factor specimens.

 

Company Qualifications

 

 

FAQ

1)In what ways does the MEBT-4300T1 Comprehensive Transformer Loss Parameter Tester demonstrate operational convenience?

- Features an 8.0-inch color LCD touchscreen for intuitive operation without complex button controls.
- Supports automatic data capture and locking, eliminating manual intervention and significantly boosting efficiency.
- Automatically switches ranges across the full current test range, eliminating the need for manual replacement of current measurement modules.
- Features data storage, USB export, printing, and computer control functions for convenient data processing.

2)Beyond transformers, what other equipment can the MEBT-4300T1 Comprehensive Transformer Loss Parameter Tester be applied to?

- Suitable for motor power measurement, capable of detecting motor-related electrical parameters and losses.
- Applicable for power measurement in the fan industry, meeting parameter testing requirements during fan operation.
- Capable of voltage and current measurement for 150Hz and 200Hz withstand voltage tests, suitable for withstand voltage testing scenarios of relevant electrical equipment.

3)What safety precautions must be followed when using the MEBT-4300T1 Transformer Loss Parameter Comprehensive Tester?

- Carefully read the operating manual before use; operators must possess general knowledge of electrical equipment operation.
- Avoid subjecting the instrument to severe vibration to prevent damage to internal components that could affect measurement accuracy.
- Ensure reliable grounding to eliminate electric shock hazards and safeguard operator safety.
- After completing testing, press the return key before turning off the power switch to prevent data loss or equipment malfunction.

 

Hot Tags: transformer loss parameter comprehensive tester, China transformer loss parameter comprehensive tester manufacturers, factory, Intelligent Transformer Loss Parameter Tester, transformer load and no load loss tester, Transformer Loss Parameter Comprehensive Tester, Transformer No Load Loss Tester

Send Inquiry