Intelligent Transformer Loss Parameter Tester

Send Inquiry
Intelligent Transformer Loss Parameter Tester
Details
MEBT-WII Intelligent Transformer No-Load/Short-Circuit Loss Tester measures multiple transformer parameters including no-load, short-circuit losses, harmonics, and zero-sequence impedance. It features calibration, storage, and printing functions, offering simple operation, high accuracy, and compact size. Suitable for testing requirements in the power industry
Category
Transformer Load and No Load Loss Tester
Share to
Description

Intelligent Transformer Loss Parameter Tester

 

Product Introduction

 

This instrument features a compact size, lightweight design, high measurement accuracy, excellent stability, and user-friendly operation. It fully replaces the traditional multi-meter method for measuring transformer losses and capacity. With simple wiring and convenient testing and recording capabilities, it significantly enhances work efficiency. It features a large-screen true-color LCD display with graphical menus and English prompts. Its multi-parameter display interface integrates multiple parameters on a single screen, offering a user-friendly interface that is simple and efficient to operate. This makes it the preferred choice for power users at all levels.

 

Product Parameter (specification)

 

1. Input Specifications

Voltage measurement range

0~750V wide range.

Current measurement range

0~20~100A with automatic or manual range switching.

2. Accuracy

Voltage

±0.1%

Current

±0.1% of full scale

Power

±0.1% (CosΦ > 0.1), ±0.2% (0.05 < CosΦ < 0.1)

3. Operating Temperature

Operating Temperature

-10°C to +40°C

4. Power Supply

Operating Power Supply

AC 160V to 265V

5. Insulation

(1) Insulation resistance between voltage/current inputs and chassis ≥100MΩ.

(2) Withstands 2kV (RMS) power frequency voltage between input terminals and chassis for 1 minute.

6. Dimensions

32cm × 24cm × 13cm

7. Weight

3kg

 

Product feature and application

 

1. Measures no-load current, no-load losses, impedance voltage, load losses, and zero-sequence impedance for various transformer types.

2. Automatically performs waveform distortion correction, temperature correction (offering both approximate temperature correction and separate additional loss correction), voltage correction (no-load testing under non-rated voltage), and current correction (short-circuit testing under non-rated current conditions). Ideal for facilities lacking short-circuit testing capabilities for larger capacity transformers.

3. Measures three-phase voltage, three-phase current, average voltage, average current, two-phase active power (using dual-wattmeter method, displaying only A and C phase power), and total power.

4. Measures 2nd to 42nd harmonic content for each phase voltage and current, along with total distortion ratio (harmonic distortion) for each signal.

5. Displays harmonic spectrum diagrams for each phase's voltage and current, providing an intuitive overview of harmonic content at each frequency.

6. Wide voltage measurement range: Measures voltages up to 750V without requiring range switching, ensuring accuracy. Incorrect voltage range selection will not damage the instrument.

7. Large screen with full English menu and operation prompts enables user-friendly interaction. Conductive rubber keys simplify operation, while the high-brightness true-color LCD display remains visible in all seasons.

8. Users can instantly print test results via the built-in micro printer.

9. All test results can be saved in record format for future reference.

10. Built-in real-time clock displays current date and time, automatically storing test timestamps alongside recorded data.

 

Prodection details

 

Suitable for all types of transformers, it measures parameters such as no-load current, losses, short-circuit losses, and impedance voltage. It supports harmonic content, distortion rate, and zero-sequence impedance measurements, meeting parameter testing requirements under various test conditions

 

Company Qualifications

 

 

FAQ

1)What are the voltage measurement range and accuracy of the MEBT-WII Intelligent Transformer No-Load/Load Loss Tester?

Answer: The voltage measurement range is 0~750V with a wide-range capability, ensuring accuracy without requiring range switching. The voltage measurement accuracy is ±0.1%.

2) What are the main test items supported by this instrument?

Answer: Core tests include single-phase/three-phase no-load testing, single-phase/three-phase short-circuit testing, and zero-sequence impedance testing. It also measures electrical parameters (voltage, current, power, frequency, etc.), harmonic content from 2nd to 42nd harmonics, and total harmonic distortion (THD). Harmonic distribution can be visually analyzed via spectrum analysis.

3)What are the key precautions for three-phase short-circuit testing?

Answer: 1. The low-voltage side must be properly short-circuited using dedicated shorting cables; otherwise, test data will be compromised. 2. If ring-type current transformers are installed on the bushing of the high-voltage or medium-voltage side, their secondary sides must be short-circuited before testing. 3. Wiring must strictly follow the manual. All test wiring operations must be performed with the tested line grounded to prevent electric shock from induced voltages.

 

Hot Tags: intelligent transformer loss parameter tester, China intelligent transformer loss parameter tester manufacturers, factory, Transformer Parameter Tester, Transformer Core No Load Test Device, Transformer No Load Loss Tester, Transformer Loss Parameter Comprehensive Tester, Intelligent Transformer Loss Parameter Tester