MOEORW-WQZ52 The SF6 comprehensive tester is a dedicated testing device for SF6 insulating gas in electrical equipment, which can measure three indicators—dew point, purity, and decomposition products—in one machine.
Equipped with a high-precision sensor and temperature compensation, anti-interference, and pump pressure cleanup design, it features touch operation, AC/DC dual power supply, and data storage, printing, and export capabilities, ensuring high efficiency and accuracy.
It is widely used in the operation, maintenance and testing of SF6 gas equipment in industries such as power, chemical, metallurgy, steel and gas.
Category
SF6 Gas Analyzer
Share to
Description

Product Introduction

 

The SF6 Comprehensive Tester is professionally designed for testing the insulating gas parameters of SF6 electrical equipment . It employs high-performance sensors to measure dew point, purity, and decomposition products, ensuring accurate and stable test results. Equipped with a unique gas path structure and a high-precision electronic flow meter, it features fully automatic detection, making SF6 gas analysis more precise. A single measurement can complete the testing of three parameters, significantly reducing user workload and improving work efficiency. The instrument integrates numerous functions such as real-time measurement, power management, time management, file storage, and parameter setting. It incorporates advanced sensor and information technology, and features touchscreen operation and a user-friendly human-machine interface, making it an ideal device for SF6 gas measurement.

 

Product Parameter (specification)

 

[SF6 Gas Decomposition Products Detection Module]

Measurement range

[SO 2 ]0~100 µl/l , [H 2 S]0~100 µl/l , [ HF ]0~ 10 µl/l , [CO]0~ 500 µl/l

accuracy

SO₂ , H₂S : ± 1 µl/l for measured values ≤ 10 µl / l ; ± 10 % for measured values > 10 µl/l .

CO: ± 5 µl/ l for measured values ≤ 50 µl /l ; ± 10 % for measured values > 50 µl/l .

HF: ±30%

Repeatability

SO₂ , H₂S , HF : ±0.5 µl /l for measured values ≤10 µl/l ; ± 5 % for measured values > 10 µl/ l .

CO: ± 2 µl/l for measured values ≤ 50 µl/l ; ± 5 % for measured values > 50 µl/l .

resolution

SO₂ , H₂S , HF , CO : 0.1 µl/l

Response time

≤ 60s

 

[SF 6 Purity Detection Module

Measurement range

0 to 100%

accuracy

≤± 0.5 %

Repeatability

≤± 0.2 %

resolution

0.01%

Response time

≤ 60S

 

[ SF 6] Humidity detection module

Dew point range

- 80 ℃ ~ +20℃

Measurement accuracy

≤ ± 0.5 ℃ ( within the calibration range )

Micro water range

0.05- 23100 μL/L

Measure response time (+20℃)

-60℃ → 20℃ 5S [30s]

20℃→-60℃ 30S[300S]

resolution

Dew point : 0.1℃

Micro water : 0.1ppm (100ppm~1000ppm) 0.01ppm (10ppm~100ppm)

Repeatability

±0.2℃

Flow rate adjustment 1 : 0.2 L/min; Flow rate adjustment 2: 0.5-0.6 L/min

 

Twenty three​ Overall parameters

Charging power supply

220VAC±10% 50HZ

Battery

12V 17.5AH lithium battery

Usage time

>10h

Display screen

7-inch color touchscreen

Sample gas pressure

≤1.0Mpa

size

360×1 55 ×3 25mm

weight

Approximately 6.5 kg

 

Product features and applications

 

  • Dual-channel flow control design, unaffected by pressure fluctuations
  • High-precision electronic flow meter with flow over limit alert
  • Dynamic switching of measurement objects and real-time data display
  • Power-on zero point and slope self-calibration function
  • Sensor anti-cross-interference technology
  • Gas path residual gas cleaning function
  • Ultra-large capacity lithium battery, AC/DC dual-use
  • Large-capacity information storage , one-click USB data export function
  • Thermal silent printer , fast on-site printing

 

Prodection details

 

SF6 gas comprehensive tester can be widely used in power, chemical, defense industry, metallurgy, steel, gas industry and other fields to measure various indicators of gas .

 

Company Qualifications

 

 

FAQ

 

Q: Are you a factory or a trading company?

A: We are a professional manufacturer of testing equipment.

Q: How is the after-sales service?

A: The warranty period is 12 months. After the warranty period, we also provide lifetime service paidrepair or service.

Q: How is the after-sales service?

A: The warranty period is 12 months. After the warranty period, we also provide lifetime service paidrepair or service.

Q: What about transportation?

A: It depends on your requirements. We can ship to your airport by air, to your seaport by sea, or to your office by courier.
We also accept cooperation with your shipping agent.

Q: Are your keyboard, interface, software, and manuals in English?

A: Yes, if you are using the English version of the keyboard, interface, software, and manual and require other languages, please contact us for confirmation.

 

Hot Tags: sf6 comprehensive analyzer, China sf6 comprehensive analyzer manufacturers, factory, SF6 Dew Point And Purity Tester, SF6 Gas Comprehensive Analyzer, SF6 Gas Quantitative Leak Detector, Fully Automatic SF6 Density Relay Calibrator, SF6 Gas Dew Point Tester, Diffusion SF6 Gas Detector

Send Inquiry