220kV Containerized PD-Free AC Resonant Test System

Send Inquiry
220kV Containerized PD-Free AC Resonant Test System
Details
System self-PD ≤ 10pC – no background noise subtraction required
Fiber-optic isolation on HV side – counterattack overvoltage does not damage the control cabinet
Series/parallel reactor combination – one system covers multiple voltage levels
Category
Partial Discharge Test Equipment
Share to
Description

220kV Containerized PD-Free AC Resonant Test System

 

product Introduction

 

Unlike stationary extra-high-voltage laboratory systems, the MOEORW-WPB260 220kV system is built for high mobilization and field versatility. Housed in a 9.5-ton heavy-duty container, it integrates the entire resonant testing loop into a transit-hardened tactical unit, bridging factory acceptance testing (FAT) and rapid site acceptance testing (SAT)

 

product Parameter (specification)

 

Parameter Specification Value Proposition
System Partial Discharge Level ≤10pC Extremely low self-background noise ensures no interference with the true PD signal reading of the test object, guaranteeing authoritative test results and avoiding return losses caused by misjudgment.
Output Voltage Waveform Distortion ≤1.0% Pure sine wave output with extremely low harmonic content ensures the authenticity of the test voltage, particularly suitable for aging assessment of waveform-sensitive insulation materials.
Output Frequency Stability ≤0.05% Frequency remains drift-free during prolonged operation, ensuring sustained stable resonance and avoiding breakdown risks caused by voltage transients due to frequency fluctuations.
Full-load Continuous Operation Duration ≥180 min A single voltage ramp-up completes the entire transformer induced withstand voltage and PD testing process without interruption for cooling, significantly improving on-site operational efficiency.
Fiber-optic Isolation Control Complete electrical isolation between HV and LV sides Even if flashover breakdown occurs on the test object, counterattack overvoltage cannot transmit through the fiber-optic cable to the control cabinet, fundamentally protecting operators and core control components.
Excitation Transformer HV Taps 2×(±5/10/35kV)multiple adjustable taps One system covers test objects at multiple voltage levels, eliminating the need for distributors to maintain separate inventory for each voltage class, substantially reducing warehousing costs.

 

Product feature

 

■ Transit-Hardened Structural Defense MatrixTraditional low-PD reactors face insulation risks during transport. The MOEORW-WPB260 employs a shock absorption cradle and mechanical lock-down rack to isolate dielectric components from road vibrations, maintaining an ultra-clean self-PD floor of ≤10pC at 220kV.
■ Intelligent Dual-Mode Tuning & Frequency-Shifting MatrixField testing involves severe electromagnetic noise. Operating across 20Hz–300Hz, the solid-state inverter actively shifts frequencies away from 50Hz/60Hz grid harmonics. An expert manual override allows 0.1Hz fine-tuning for precise partial discharge capture without shielded enclosures.

 

Product Application

 

5

The MOEORW-WPB260 220kV system is a versatile, containerized mobile test platform featuring a reconfigurable reactor matrix for rugged field use. It optimizes asset utilization across three key power grid applications:

  • Power Transformers (110kV / 220kV): Supports FAT/SAT testing, including line-terminal AC withstand, induced overvoltage (DVDF), and partial discharge (PD) screening down to ≤10pC in noisy field environments.
  • Gas Insulated Switchgear (GIS / GIL): Provides high-voltage resonance for flashover commissioning, detecting particle contamination, protrusions, and floating discharges prior to energization.
  • High-Voltage XLPE Cables (110kV / 220kV): Uses parallel configuration for high output currents on long underground circuits, delivering pure sinusoidal waves compliant with IEC 60840 and IEEE 400.4 standards.

 

Product Model and Selection Guide

     

Our MOEORW-WPB260 Series offers a modular, containerized architecture that easily adapts to varying fieldwork requirements. By choosing different reactor matrices and excitation profiles, you can tailor your system to perfectly match your specific testing targets:

Model / Configuration Core Matrix Setup Max. Testing Voltage Typical Applications & Load Capacity
WPB260-S (Standard Field Set) 4 x 20kV/5A/6H Low-PD Reactors 110kV / 132kV Optimized for standard SAT/FAT insulation screening of 110kV main power transformers and substation GIS bays.
WPB260-P (Plus Power Grid Set) 6 x 20kV/5A/6H Low-PD Reactors 220kV / 230kV Designed for heavy-duty testing of 220kV power transformers, GIL systems, and medium-length urban underground distribution networks.
WPB260-E (Extended Reach Set) 6 x 20kV/5A/6H Reactors + Multi-Tap Excitation 220kV Downward to 35kV The ultimate choice for third-party testing contractors. Handles 220kV full-scale SAT while easily down-matching to 35kV/110kV capacitive cable lines.

How to Select Your Configuration:

Check Test Object Capacitance (CX): Ensure your total equivalent capacitance fits the resonance frequency formulaproduct-76-32within the 20Hz–300Hz tracking window.

Verify Field Input Power: The system operates on standard 380V ± 10% three-phase power (50Hz/60Hz). For remote unpowered grid sites, a standard 300kW mobile diesel generator set is recommended.

Confirm Target PD Threshold: If your required background noise is strictly ≤10pC, the vehicle-mounted shielded container configuration must be deployed to eliminate local electromagnetic spikes.


 

FAQ

 

Q: How does the containerized enclosure protect sensitive reactors from transport vibrations during off-road transit?

A: The MOEORW-WPB260 features integrated industrial-grade shock-absorption bases and heavy-duty reactor lock-matrices. All high-voltage reactors and excitation components are firmly secured with rigid bracing and premium dampening pads inside the enclosure. This rugged design eliminates any transit-induced physical shifts, ensuring that the system's self-partial discharge remains strictly stable at ≤10pC for immediate field deployment after long-haul transit.

Q: Substation environments have heavy electromagnetic noise. How does this system isolate the site PD signals?

A: The system is designed with advanced anti-interference and isolation features to handle complex electromagnetic environments effectively.

Q: Our fleet tests both transformers and long XLPE cable runs. Can this system be reconfigured for different loads?

A: Yes, the modular architecture allows flexible configuration adjustments to accommodate various testing loads such as transformers or cables.

 

 

 

Hot Tags: 220kV Containerized PD-Free AC Resonant Test System, China 220kV Containerized PD-Free AC Resonant Test System manufacturers, factory