5kVA-50kV SF6 Gas-Insulated No-PD Test System

Send Inquiry
5kVA-50kV SF6 Gas-Insulated No-PD Test System
Details
Lightweight, oil-free, and low partial discharge (≤5pC) withstand voltage test system with SF6 insulation. Stable, safe, and ideal for on-site mobile testing and accurate insulation defect detection of power equipment.
Category
Partial Discharge Test Equipment
Share to
Description

Product Introduction

 

The MOEORW-WPG15-5kVA/50kV no-partial-discharge withstand voltage test system adopts SF₆ gas insulation and a lightweight structure, with partial discharge ≤5pC. It is specially designed for on-site non-PD withstand voltage and insulation testing. Lighter and pollution-free compared with traditional oil-immersed types, it outputs stable and clean power frequency high voltage, accurately identifies insulation defects, and is ideal for frequent mobile operations and high-precision PD tests.

 

Product Parameter (specification)

 

 

Rated Capacity 5kVA
Input Voltage AC220V±10%
Output Voltage 0–50kV
Output Current 100mA
System Partial Discharge ≤5pC
Insulation Medium SF₆ Gas
Voltage Accuracy AC 1.5%
Power Distortion <3%

 

Product Feature

 

  • SF₆ gas insulation, leak-tight, oil-free, eco-friendly and safe
  • Lightweight for fast on-site deployment and frequent testing
  • Zero-position interlock + overcurrent protection prevents misoperation
  • Clean high-voltage output and stable test results
  • AC/DC dual-use; DC withstand voltage available with an external silicon stack
  • Easy maintenance: regular pressure check and cleaning only

 

Product Application

 

Power systems

GIS, switchgears, cables, transformers, CVTs, instrument transformers

 

Industrial sites

motors, electrical components, insulation material withstand tests

 

Testing institutions

delivery inspection, preventive tests, PD measurement

 

Railway, metallurgy, petrochemical

high-voltage equipment inspection and acceptance

 

Company Qualifications

 

 

FAQ

 

Q: Why SF₆ insulation?

A: SF₆ provides high insulation strength, nonflammability, low PD, and lighter weight.

Q: What is the normal operating pressure?

A: 0.2–0.35MPa; recharge below 0.15MPa.

Q: Can it do PD test directly?

A: Yes, with a PD detector, coupling capacitor, and protective resistor.

Q: How long can it run continuously?

A: Max 30 minutes at rated load; cool down 5–10 times the working time.

Q: Can it be used in humid weather?

A: Recommended humidity ≤85%; clean insulation parts with alcohol in rainy seasons.

 