Open-Loop Low-Current Tester For Excitation Systems

Send Inquiry
Open-Loop Low-Current Tester For Excitation Systems
Details
All-in-one design, no extra testing equipment needed
Intelligent auto fault diagnosis, fast excitation fault location
Full functions for complete excitation open-loop test
Factory direct supply, bulk & OEM customization available
Category
Generator Testing Equipment
Share to
Description

MOEORW-WFC63 Open-Loop Low-Current Tester for Excitation Systems

 

Product Introduction

 

         Replace the traditional separate combination of power supply, resistive load and waveform recorder. This all‑in‑one unit completes excitation regulator pulse test, phase‑shift & inverter test, dual‑channel switching test and thyristor bridge fault detection. Single unit meets overhaul commissioning requirements for power plants; bulk orders support factory‑end quality inspection for complete‑set manufacturers and project centralized procurement for engineering contractors.

 

Background & Industry Pain Points

 

    Traditional open‑loop excitation tests require separate 380V power supply, high‑power resistive load and waveform recorder, bringing three major on‑site problems:

     Complicated wiring and long preparation time. Assembling test circuits normally takes at least 1.5 hours for one crew, raising high labor cost for mass unit testing.

     High safety risk. Multiple discrete devices lead to messy wiring; phase loss or wrong phase sequence may burn excitation boards.

Inefficient fault troubleshooting. Waveforms cannot be synchronously saved; technicians have to disconnect wires section‑by‑section to find thyristor or pulse‑loop failures, extending unit downtime.

     This tester is developed in accordance with DL/T 846 Testing Specification for Power System Protection and Automatic Equipment. It integrates power conversion module, dedicated power load and 7‑inch touch waveform recording unit into one cabinet to solve above‑mentioned field pain points. It has become standard static‑test equipment for domestic power plants and complete‑set manufacturers.

 

Technical Parameters

 

Item Standard Specification Bulk‑Order Custom Option Remarks for Credibility
Input Power 3‑phase 4‑wire 380V AC 50Hz 400V 3‑phase input for overseas markets Industrial‑grade power supply, fits most domestic and foreign power‑station sites
3‑phase AC Output Voltage 100V AC 60V / 120V / 230V configurable Matches low‑voltage test modes of mainstream excitation regulators; unified output setting for bulk batches
Waveform Sampling DC voltage & pulse real‑time display Expand multi‑channel synchronous acquisition 1MHz high‑speed AD chip, distortion‑free waveform recording, meets DL/T recording requirements
Data Storage Local U‑disk storage; export CSV & editable test reports Custom report template with client brand logo Reports comply with domestic power‑industry acceptance filing standards
Safety Protection Phase‑loss detection, reverse‑phase‑sequence alarm, over‑current protection Add remote fault‑diagnosis module Every unit passes 72‑hour full‑load aging test before delivery
Display 7‑inch industrial touch screen Upgrade to 10‑inch screen for bulk orders ‑10℃ ~ 50℃ stable operation, visible under strong field sunlight

 

Product features and applications

 

All‑in‑one integrated design, no extra peripheral instruments required

Integrated power supply, power load and waveform recording. No extra oscilloscope, adjustable resistive load or isolation power supply needed. Why reliable: Self‑developed power‑conversion module. Nickel‑chromium alloy non‑inductive resistors from our own load production line; resistor temperature rise ≤35℃ under full load. Client value for bulk purchase: Simplify procurement list, reduce multi‑supplier communication & after‑sales workload. Single‑unit users finish field work with one person and less transporting workload.

Intelligent automatic fault identification; locate thyristor & pulse‑loop faults rapidly

Built‑in diagnostic algorithm automatically detects missing pulses, damaged thyristors, abnormal phase‑shift angle and broken synchronous signals; fault points are marked directly on screen. Why reliable: Proven by over 200 domestic thermal & hydro power plants. On‑site fault‑locating efficiency improved by 80%. Algorithm iterated based on thousands of real‑site waveform cases stored in factory database. Client value for bulk purchase: Less dependence on senior excitation specialists; junior technicians can finish diagnosis, cutting enterprise labor cost. Power‑plant groups shorten unit downtime during overhaul.

Full‑function coverage for complete open‑loop excitation tests; one unit for multiple purposes

Supports pulse‑verification, strong‑excitation simulation, inverter test, dual‑regulator channel switching, full‑range phase‑shift test and phase‑sequence check. Why reliable: Compatible with mainstream excitation rectifier cabinets at home and abroad. Client value for bulk purchase: Distributors stock one model for all mainstream cabinet types to reduce inventory pressure. Complete‑set manufacturers only need 2‑3 units per production line for full‑range quality inspection.

Compact & portable for field mobility

Integrated cabinet with carry handle; total weight ≤16 kg. Why reliable: Aviation‑aluminum integrated stamping cabinet; passed drop‑test, high‑low‑temperature and humidity environmental tests. Shock‑resistant for outdoor site transportation. Client value for bulk purchase: Easy deployment for multiple field teams, lower transport cost. More units fit one shipping carton to cut logistics expense for bulk shipments.

Multi‑layer safety protection, minimize on‑site test risks

Audio‑visual alarm for phase loss, over‑voltage, over‑current and reverse phase sequence; hardware interlock protection for test loops. Why reliable: Passed third‑party power‑equipment safety test with CNAS‑recognized test report available. Client value for bulk purchase: Satisfy safety‑acceptance requirements for power‑industry bidding; avoid equipment‑burning & electric‑shock risks for on‑site teams under your management.

Export test‑ready data & standardized acceptance reports

Real‑time waveform screenshot, auto‑save test data to U‑disk. Editable acceptance‑report output. Switchable Chinese / English UI. Why reliable: Exported reports match power‑plant archive‑filing rules. Client value for bulk purchase: Distributors can customize brand‑embedded report templates to improve end‑user satisfaction. Complete‑set manufacturers realize traceable mass‑production quality records.

Flexible customization for bulk orders

Customizable output voltage, screen size, UI language, body logo and report template. OEM & ODM available. Why reliable: In‑house R&D team with 10‑year experience in power‑testing‑equipment customization. Monthly customized‑order capacity: 50 units. Client value for bulk purchase: Overseas dealers obtain full‑English software & CE‑compliant documents; domestic complete‑set manufacturers launch self‑branded product lines

 

 

 

Prodection details

 

 
 

Equipment testing and commissioning

Comprehensive testing of the excitation control system, open-loop characteristic testing of various excitation system rectifier cabinets, and open-loop low-current testing of the excitation system during static commissioning and overhaul of generator sets.

 
 
 

Fault location and analysis

Rapidly locate excitation system faults, analyze generator excitation system accidents, and troubleshoot hardware faults such as measurement, synchronization signals, pulse circuits, and thyristor trigger circuits.

 
 
 

Functional verification and testing

Verification of the excitation regulator's pulse output, forced excitation, and inverter functions; testing of the excitation regulator's dual-machine switching function to ensure that all functions of the excitation system are normal and reliable.

 

 

Standard Packing List

 

No. Item Qty Unit
1 Main Unit 1 set
2 3-Phase Input Cable 1 set
3 3-Phase Output Cable 1 set
4 DC Test Cable 1 set
5 Conduction Angle Cable 1 set
6 Test Clips 10 pcs
7 USB Flash Drive 1 pcs
8 User Manual 1 copy
9 Factory Test Report 1 copy
10 Certificate & Warranty Card 1 copy

 

FAQ

Q: How is after‑sales handled for multiple‑unit orders?

Exclusive client file will be created for bulk buyers. Spare parts are prioritized in stock. On‑site engineer support can be arranged within 48 hours for critical failures.

Q: Are you a manufacturer or a trading company?

A:We are a direct manufacturer specializing in high-voltage testing equipment. We have our own R&D team and production facility, which allows us to offer factory-direct pricing and strict quality control.

Q: What is your warranty and after-sales policy?

A:All units come with a 12-month warranty. After the warranty expires, we provide lifetime technical support and paid maintenance services.

Q: Do you support English language interfaces?

A: Yes, our standard models feature English keyboards, software, and user manuals. If you require other languages, please contact us to check availability for customization.

 

Hot Tags: open-loop low-current tester for excitation systems, China open-loop low-current tester for excitation systems manufacturers, factory, Multi-Function Generator Rotor AC Impedance Tester, Water Cooled Generator Insulation Resistance Tester, Power Recorder Analyzer, generator testing equipment, Turbine Speed Control System Simulation Tester, Water Cooled Motor DC Withstand Voltage Tester

Send Inquiry