Double Grounded Circuit Breaker Analyzer

Send Inquiry
Double Grounded Circuit Breaker Analyzer
Details
MOEORW-W5126KD High-Voltage Switch Dynamic Characteristics Tester provides accurate, all-in-one mechanical property testing for vacuum, SF6, oil, GIS and overhead circuit breakers.
It supports 12-channel synchronous measurement, high-power DC output, multiple sensors and trigger modes, ideal for field and factory testing.
Category
Circuit Breaker Analyzer
Share to
Description

Double Grounded Circuit Breaker Analyzer

 

Product Overview

 

MOEORW-W5126KD is an industrial computer-based dynamic characteristics tester designed for fully automated mechanical property testing of high-voltage circuit breakers. It supports time, speed, travel, bounce, reclosing, coil current/resistance, and operating voltage tests for SF6 switches, GIS, vacuum switches, oil switches, overhead switches, and contactors. The instrument integrates a high-power DC power supply, multiple sensor interfaces, data storage, waveform analysis, and printing functions, suitable for factory inspection, on-site preventive testing, and hand-over testing of switchgears up to 35kV.

 

Technical Parameters

 

ItemSpecification
Power SupplyAC 220V±10%, 50Hz±10%
Operating EnvironmentTemperature: -20℃~+45℃; Humidity: ≤80%RH; Atmospheric Pressure: 86~106kPa
Insulation Resistance>2MΩ
Dielectric Strength1.5kV AC for 1min, no flashover or arcing
Time MeasurementRange: 64000.0ms; Resolution: 0.1ms; Error: ≤±(0.1%rdg+0.1)
Speed MeasurementRange: 20.00m/s; Resolution: 0.01m/s; Error: ≤±(1%rdg+0.01)
Travel MeasurementVacuum CB: 50.0mm; SF6 CB: 300.0mm; Oil CB: 1000.0mm; Resolution: 0.1mm
Coil CurrentRange: 40.00A; Resolution: 0.01A; Error: ≤±(1%rdg+0.1)
Coil ResistanceRange: 30.0kΩ; Resolution: 0.1Ω; Error: ≤±(1%rdg+0.1)
Output DC VoltageDC 0~270V adjustable; Resolution: 1V; Error: ≤±1%rdg; Max current: 30A
Energy Storage OutputMax starting current: 25A; Suitable for ≤35kV vacuum CB (DC110V/DC220V)
Dimension & Weight420mm×345mm×230mm; 8kg

 

Main Functions & Features

 

1. Multi-port Synchronous Measurement

1. Technical Design: 12 independent break detection channels with dual common grounds (GND1, GND2).2. Performance: Measures inherent switching time, phase synchronization, and phase-to-phase synchronization simultaneously.3. Value: Supports complete dynamic characteristic testing for 3-, 6-, and 12-break switches.

2. Full Dynamic Parameter Test

1. Technical Design: Built-in high-speed sampling and waveform analysis module.2. Performance: Captures closing/opening bounce, rebound amplitude, reclosure sequence (O-CO, C-O, O-C-O), and current waveform.3. Value: Provides complete data for mechanical performance evaluation and fault diagnosis.

3. Wide Compatibility Speed Testing

1. Technical Design: Supports acceleration, rotary, linear travel, and contact sensors; built-in 10+ predefined speed definitions and custom speed definition.2. Performance: Adapts to IEC standards and manufacturer-specific speed definitions (e.g., 10ms, 6mm, 10mm sampling).3. Value: Universal for domestic and international CB models without manual cursor calculation.

4. High-power DC & Control Output

1. Technical Design: 30A high-power adjustable DC supply; 25A energy-storage output; unlock power supply.2. Performance: Drives CB operating coils and motor energy storage; supports low-voltage operating voltage test.3. Value: Eliminates external power supply; simplifies on-site wiring and operation.

5. Trigger & Control Flexibility

1. Technical Design: Internal, external, sensor, manual, and current trigger modes.2. Performance: Compatible with motorized and manual switches; supports AC/DC operating mechanisms.3. Value: Suitable for substation on-site test and switch factory production test.

6. Data Management & Output

1. Technical Design: 1000-group internal storage; USB; RS232; built-in thermal printer.2. Performance: Stores test data with real-time clock; supports waveform display, data analysis, and report printing.3. Value: Facilitates data archiving, traceability, and third-party report submission.

7. Durable & User-friendly Design

1. Technical Design: Industrial PC structure; wide-temperature backlight LCD; Chinese menu operation.2. Performance: Stable in harsh on-site environments; one-action test displays full data and waveforms.3. Value: Reduces operation complexity and improves test efficiency.

 

Application Scope

 

  • Vacuum circuit breakers (10kV, 35kV)· SF6 circuit breakers and GIS equipment· Oil circuit breakers· Overhead switches and contactors· Isolation switch endurance testing· Factory delivery test, substation hand-over test, periodic preventive test

 

Product Structure & Panel Layout

 

  • Protection Ground Terminal: Reliable connection to on-site earth.
  • Break Detection Ports: A1/B1/C1~A4/B4/C4, GND1/GND2 (12 channels).
  • Control Interfaces: Internal trigger, external trigger, energy storage, unlock power supply.
  • Sensor Interface: For rotary, linear, acceleration, and contact sensors.
  • Communication & Output: USB, RS232, built-in thermal printer.
  • Control Keys: ESC, OK, direction keys, reset; LCD contrast adjustment.
  • Power Module: AC 220V input, integrated fuse and switch.

 

Daily Maintenance

 

  • Store in dry, non-corrosive environment when not in use.· Power on the instrument for 2 hours every month for long-term storage.· Use in dry and flat environment to avoid moisture and mechanical damage.· Do not disassemble the instrument to avoid high-voltage hazards and warranty invalidation.

 

Troubleshooting

 

1. CB does not actuate during internal trigger test

  • Check DC output voltage; restart after cooling if over-temperature protection is activated.o Verify CB lock is released; use unlock power supply or external trigger mode.o Check control wiring and coil circuit continuity.

2. No test data displayed after CB action

  • Confirm ground wire and break wiring are correct; only one end of CB can be grounded.o Use manual closing/opening test instead of auto-test.

3. Printer feeds paper but no print content

  • Reinstall thermal paper with correct side facing up.o Replace print head if damaged.

4. Abnormal waveform or inaccurate speed data

  • Check sensor installation coaxiality and fixation.o Verify sensor type and speed definition match the CB model.

 

FAQ

 

1.Q: Why must the ground wire be connected first before wiring?

A: High induced voltage exists on HV CB breaks. Pre-grounding connects the discharge loop to protect the instrument and ensure test safety.

2.Q: What is the maximum allowable starting current for energy storage motor?

A: The starting current must not exceed 25A; otherwise, the internal DC power supply may be damaged.

3.Q: Can the instrument test AC operating mechanism CB?

A: Yes, use external trigger mode and on-site AC control power supply.

4.Q: How to verify the break detection channels are normal?

A: Enter Setting → Status Detection; short each break to ground; the display changes from "Open" to "Close" to confirm normal function.

5.Q: What sensors are standard with the instrument?

A: Rotary sensor and 50mm linear travel sensor are standard; acceleration and contact sensors are optional.

 

 

Hot Tags: double grounded circuit breaker analyzer, China double grounded circuit breaker analyzer manufacturers, factory, AC DC Gradient Coordination Tester, breaker tester, Circuit Breaker Analyzer CB Analyzer, Circuit Breaker Characteristic Analyzer, Circuit Breaker Dynamic CharacteristicTester, HV Circuit Breaker Tester

Send Inquiry