1000mA Earth Leakage Circuit Breaker Tester
Product Overview
This MOEORW-WKL10 tester is a professional handheld device for verifying residual current device performance. It accurately measures tripping current, non-tripping current, and tripping time across single-phase two-wire, three-phase three-wire, and three-phase four-wire systems. With dedicated wiring diagrams and auto-step testing, it delivers reliable results for routine inspection and compliance verification.
Technical Specifications
| Item | Specification |
| Rated Voltage | AC 220 V / AC 380 V |
| Test Voltage Limit | ≤ AC 250 V |
| Power Supply | 6 V DC (4×AA batteries) |
| Current Steps | 30, 50, 75, 100, 150, 200, 250, 300, 500, 1000 mA (10 steps) |
| Time Measurement | 0–799 ms |
| Current Accuracy | Class 1 |
| Time Accuracy | Class 0.5 |
| Ambient Temp | 0 °C – 40 °C |
| Humidity | < 85% RH |
| Dimensions | 195 × 101 × 42 mm |
Key Features
- Three standardized wiring modes for single-phase, three-phase three-wire, and three-phase four-wire RCDs with clear terminal labeling.
- Auto-step detection automatically raises current level every 1 second until tripping, capturing real operating parameters.
- One-key reset clears readings instantly and resets the instrument for continuous testing.
- Stable measurement under AC 250 V max test voltage, protecting both instrument and device under test.
- Shock-resistant casing suitable for harsh on-site conditions with vibration and bump protection.
Application Fields
- Factory calibration and quality control of RCD manufacturers
- Installation inspection and periodic maintenance of power distribution systems
- Safety compliance testing in industrial plants, mines, and construction sites
- On-site troubleshooting by electrical service and utility companies
Compliance & Standards
- IEC 61557-6: Requirements for equipment testing RCD effectiveness in low-voltage systemsIEC Webstore
- IEC 61557-13: Performance requirements for handheld leakage current measuring clamps and sensorsIEC Webstore
- National standards for residual current operated protective devices
FAQ
1. Q: What preparations are required before starting a test?
A: Confirm correct wiring, reliable grounding, closed test compartment doors, normal instrument communication, and valid test parameters.
2. Q: Why does the system fail to start the test?
A: Check emergency stop status, compartment door interlock, power supply, PLC connection, and instrument online status.
3. Q: How to retrieve historical test data?
A: Enter the corresponding test number in the software to query and export stored data and reports.
4. Q: What should I do if test data is unstable?
A: Recheck wiring connections, re-calibrate instruments, eliminate electromagnetic interference, and verify power supply stability.
Hot Tags: 1000ma earth leakage circuit breaker tester, China 1000ma earth leakage circuit breaker tester manufacturers, factory, circuit breaker analyzer, Circuit Breaker Analyzer CB Analyzer, Circuit Breaker Comprehensive Tester, Circuit Breaker Dynamic CharacteristicTester, Dual End Grounded Auxiliary Power Box, High voltage Circuit Breaker Double terminal Grounding Action Characteristic Testing System