3-Pipeline High Precision Buchholz Relay Tester

Send Inquiry
3-Pipeline High Precision Buchholz Relay Tester
Details
Deliver fully traceable, high-efficiency calibration for all mainstream Buchholz relays with triple independent pipelines.
It cuts lab floor occupation and manual labor while generating standardized test reports to meet metrology filing demands.
Ideal for large transformer factories and power inspection labs to boost daily verification throughput reliably.
Category
Relay Protection Tester
Share to
Description

Product Overview

 

MOEORW‑600Q3 Automatic Gas Relay Test Bench, also known as Buchholz relay calibrator and gas‑relay test device. Developed according to DL‑T540‑94 gas relay test regulation for metrological traceability. It conducts flow‑rate, volume, sealing and oil‑lack‑alarm tests for baffle‑type & double‑float‑type gas relays of φ25, φ50, φ80 caliber. Expandable for φ40 and oil‑cut‑off‑valve test. Adopts three independent test pipelines, suitable for high‑volume laboratory calibration and single‑sample test. Full set of technical documents are provided ex‑factory for metrological verification, transformer‑factory outgoing inspection and power‑operation‑maintenance laboratory use

 

Technical Specifications

 

CAN‑bus communication adopted; three independent pipelines for φ25/φ50/φ80 with stabilizing straight pipe for each channel; single‑side suspended hydraulic clamping, concentric deviation ≤±3 mm. Each unit passes temperature‑variation durability aging and individual standard‑gas calibration.

Flow‑rate test: φ25(0.6‑4.2m/s), φ50(0.6‑3.2m/s), φ80(0.6‑2.2m/s); accuracy class 1.5, flow‑meter class 0.5, resolution 0.001 m/s

Volume test: 0‑950 mL; accuracy 1.0%, resolution 0.1 mL

Sealing test: pressure 0‑250 kPa, test time 1‑60 min; pressure accuracy 0.5%, resolution 0.1 kPa

Electrical requirement: AC380V three‑phase four‑wire, total power 9.5 kW; operating environment ‑10℃~+50℃, humidity ≤85%

Physical dimension: 2900×650×1600 mm, total weight 1300 kg; oil‑tank filling 100‑120 L; 19‑inch touch industrial PC, one‑click comprehensive test, local data storage, A4 / WiFi network‑printing & historical‑record review supported.

 

Key Product Highlights

 

Three‑channel independent pipeline system: Each caliber is equipped with independent flow‑meter & stabilizing section, eliminating pipeline‑resistance interference caused by reducing joint. Fluid condition is closer to real‑world service condition.

Intelligent comprehensive‑test mode: Supports separate flow‑rate / volume / sealing test; comprehensive‑test mode runs full test sequence automatically with one click.

Complete abnormal‑protection system: Real‑time monitoring of pressure, flow and actuators. Auto stop & alarm for over‑pressure, leakage or timeout to protect bench and DUT relay.

Multi‑contact synchronous sampling: Three acquisition channels for heavy‑gas and light‑gas respectively to capture multiple contact on‑off status simultaneously.

Powerful data management: Complete historical‑record database for quick review & export‑print; remote firmware upgrade; suitable for continuous high‑volume sample test in laboratories.

 

Delivery & Supporting Services

 

‑ Standard delivery: Main test‑bench unit, full‑set caliber‑mounting flanges, signal test cables, printed operation manual, factory calibration report

‑ Technical service: On‑site commissioning guidance; hands‑on training; remote troubleshooting; 7×12‑hour engineer support

‑ Value‑added services: Metrology‑submission assistance, pre‑parameter‑setting for batch units, complete spare‑parts supply.

 

 

3-Pipeline High Precision Buchholz Relay Tester
Application Scenarios

Metrological verification for gas relays in metrology institutes & electric‑power laboratories

Mass outgoing calibration for large‑scale transformer manufacturers

Maintenance laboratories & quality‑control departments of power‑grid departments

Entrusted‑testing service for third‑party testing organizations

Test platforms for research institutes & educational institutions

 

 

 

Manufacturing & Quality‑Control Capability

 

Production‑line & supply‑chain: Standardized assembly & commissioning stations. Batch sampling inspection for incoming components. Safety stock for key materials guarantees large‑order delivery.

Calibration laboratory: Dedicated simulated‑oil‑circuit calibration system. Every unit passes assembly, aging, standard‑gas calibration and full‑unit final inspection.

R&D & qualification: Self‑developed Windows‑based test software with software copyright; compliant with industrial specifications; ISO9001 quality‑system certification.

After‑sales guarantee: Dedicated after‑sales commissioning station with abundant wearing‑part stock for short repair turnaround. Original‑factory technical support for orders of any volume.

 

Fault Troubleshooting Chart

 

Fault Manifestation

Root Cause

Corresponding Solution

Printer fails to output test data or indicator light flickers continuously

Printing paper exhausted

Refill thermal printing paper completely

Printed test report shows blank without legible text

Mismatched printing paper or reversed paper installation

Flip the paper for reinstallation or replace matching thermal printing paper

Flow velocity digital value fluctuates violently during testing

Severe on-site electromagnetic interference

Lay independent short grounding wire; relocate equipment to low-interference test area

Light gas volume test result has obvious deviation

Relay not horizontally clamped; internal volume float component failure

Re-clamp relay to horizontal state and retest; inspect light gas float function of the tested relay

No contact action feedback after long-duration flow velocity test operation

Heavy gas trip baffle mechanism of the tested relay malfunctions

Disassemble and inspect the mechanical trip structure of the Buchholz relay

 

FAQ

 

Q1: What waiting requirement exists after power-off via the green operation button?

A1: After shutting down the system through the green power button, operators must wait 30 seconds before restarting the equipment; otherwise the system will reject startup instructions.

Q2: How to correctly connect the signal alligator clips?

A2: Red clip connects light gas alarm contact terminals; black clip connects heavy gas trip terminals. Any group of contacts can be selected if the relay is equipped with multiple contact pairs.

Q3: Can manually terminated incomplete test data be saved and printed?

A3: Any test manually interrupted before full completion generates invalid data that cannot be stored or printed.

Q4: What standard should be followed for initial oil filling?

A4: Inject 100~120L qualified transformer oil marked on the equipment nameplate, keeping the liquid level 10 cm below the top edge of the oil tank.

Q5: How to safely transfer the calibration bench?

A5: Pull up caster locking handles to unlock wheels before pushing; after moving to the designated position, lift all eight leveling feet and adjust the machine to horizontal state.

 

Hot Tags: 3-pipeline high precision buchholz relay tester, China 3-pipeline high precision buchholz relay tester manufacturers, factory, 6 phase relay test set, Handheld Optical Digital Relay Protection Tester, relay protection tester, Six Phase Relay Protection Tester, Six Phase Secondary Current Injection, Three Phase Secondary Current Injection Relay Test Set