MOEORW To Unveil New Wi900PD Detector And W5087C Online PD Monitoring System At EP Shanghai 2026

Nov 25, 2026

Leave a message

EC Editorial Desk
EC Editorial Desk
Editorial desk for MOEORW exhibition highlights and customer case studies. Covering trade shows, booth updates, factory visits and real client projects, turning first-hand insights into practical stories for B2B buyers.

MOEORW to Unveil New Wi900PD Detector and Online PD Monitoring System at EP Shanghai 2026

Live demonstrations at Booth W4-M18, W4 Hall (China Pavilion Area A), December 3–5, 2026.

📅 Dec 3–5, 2026

📍 Shanghai New International Expo Centre

🎯 Booth W4-M18

 

 

 

 

Book a Meeting →

 

Partial Discharge Monitoring Launch | EP Shanghai 2026

MOEORW, a specialist in high-voltage condition monitoring and diagnostic equipment, will present two new partial discharge (PD) solutions at the 33rd China International Power Equipment and Technology Exhibition (EP Shanghai 2026), taking place December 3–5 at the Shanghai New International Expo Centre. Application engineers will be on site at Booth W4-M18 to demonstrate the MOEORW-Wi900PD Multifunctional Partial Discharge Detector and the On-line Partial Discharge Monitoring Device to utility, industrial and EPC visitors from around the world.

 

Why Partial Discharge Monitoring Matters

 

Partial discharge is one of the earliest detectable signs of insulation degradation in high-voltage assets. Left unnoticed, it can develop into catastrophic failure: unplanned outages, equipment damage and safety incidents. As grids age and renewable energy integration increases, operators are moving from scheduled maintenance to condition-based and predictive strategies. Continuous PD monitoring and reliable field diagnostics have become essential tools for protecting transformers, switchgear, GIS, cables and rotating machines.

 

New Product 1: On-line Partial Discharge Monitoring Device

 

 

Online PD Monitoring System
ONLINE MONITORING

The is a three-channel HFCT online PD monitoring system customized for long-term insulation monitoring and early fault warning on cables, switchgear and transformers. Using Rogowski-coil HFCT sensors, high-speed logarithmic detection and edge computing, it captures 3 MHz–30 MHz PD pulses in real time and transmits data over Ethernet and RS485.

 Multi-channel parallel sampling - monitors multiple circuits simultaneously for higher inspection efficiency

 Wideband, high-sensitivity acquisition with precise localization of authentic PD signals

 24/7 continuous tracking - no outages and no manual retesting required

 Embedded intelligent edge AI that analyzes data locally while filtering environmental noise

 Multi-tiered threshold alarms with event logging for predictive maintenance

 Ethernet and RS485 interfaces for integration into existing SCADA backends

Typical applications include switchgear, cable joints, transformers, GIS, substations, mines and renewable-energy booster stations.

 

New Product 2: MOEORW-Wi900PD Multifunctional Partial Discharge Detector

 

FIELD DIAGNOSTICS

The Wi900PD is an advanced handheld spot-checker that integrates intelligent data analysis, multi-mode PD analysis, ultrasonography, acoustic imaging and intelligent recognition on an Android OS with IoT connectivity. It is suited to substations, industrial plants, rail transit and utility grids.

MOEORW-Wi900PD Multifunctional PD Detector one instrument five sensing modes

 Multi-mode testing - supports AA, TEV, UHF, HFCT and AE sensors

 Smart diagnostics - an embedded AI core identifies corona, floating-potential and surface discharge patterns locally

 Rich data presentation - PRPD, TRPD, trend curves and pulses with cloud storage

 Dual high-definition screens with Bluetooth link to smartphones and tablets

 Shielded aluminium-magnesium casing that blocks substation electromagnetic interference

MOEORW-Wi900PD Multifunctional PD Detector - one instrument, five sensing modes..jpg
MOEORW-Wi900PD Multifunctional PD Detector - one instrument, five sensing modes

 

Also on Display at Booth W4-M18

 

Visitors can also see three complementary solutions: the MOEORW-W5086GS HV Rotating Machine On-line PD Monitoring System for 6 kV/36 kV motors and generators; the MOEORW-WOHLT Series Cable Oscillating Wave Partial Discharge (OWTS) Test System for 10 kV cable networks; and two new sensing products featured on the exhibition poster - the MOEORW-WWP200 Intelligent PD Sensor for RMU and switchgear, and the MOEORW-WRLU Railway Catenary Fault Monitoring Device.

W5086GS continuous PD monitoring for HV rotating machines with local DAQ units and remote diagnostics
W5086GS: continuous PD monitoring for HV rotating machines, with local DAQ units and remote diagnostics.
 
 

 

Partial discharge monitoring is moving from periodic testing to always-on intelligence. At EP Shanghai 2026, MOEORW is showing tools that give operators a clearer, earlier view of insulation health - one for continuous monitoring, one for fast on-site diagnosis. Engineers and procurement teams are invited to see them live at Booth W4-M18.

 

 

Event Details

  Event   Date
  EP Shanghai 2026 - The 33rd China International Power Equipment and Technology Exhibition   December 3–5, 2026
       
  Venue   Address
 

Shanghai New International Expo Centre

  No. 2345 Longyang Road, Pudong, Shanghai, China
       
  Halls   Booth
 

N1–N5, W4 and W5

  W4-M18 - W4 Hall, China Pavilion Area A

 

About MOEORW

 

MOEORW designs and manufactures partial discharge detection and high-voltage condition monitoring equipment for electrical industries worldwide. Its portfolio covers portable detectors, online monitoring systems, intelligent PD sensors and cable diagnostic platforms, supporting customers across the full asset lifecycle - from commissioning tests to online monitoring and predictive maintenance.

Send Inquiry