5kVA 100kV AC Hipot Test Set

Send Inquiry
5kVA 100kV AC Hipot Test Set
Details
5kVA / 100kV / 50mA — Covers higher voltage hipot tests
Zero-Voltage Start — Safe ramp-up every cycle
Time Relay + Alarms — Precise test duration control
Compact Design — Small footprint, easy to move
CE Certified — Meets international safety standards
Single-Phase 220V Input — Runs on standard power
Wide Applications — Transformers, cables, insulators, switchgear
Low Maintenance — Rugged design for long-term use
Category
AC Hipot Test Set
Share to
Description

 

 

Products Description

 

 AC Hipot Test Set

High-Voltage AC Withstand Testing for Medium and High-Voltage Equipment

 

Moen's MEYDQ-W5kVA-100kV AC Hipot Test Set delivers 100kV output at 5kVA / 50mA for insulation strength testing on equipment that requires higher test voltages.

Rated at 5kVA with a maximum output of 100kV / 50mA, this test set covers transformers, CTs/PTs, insulators, switchgear, cables, and other high-voltage equipment up to 100kV. Zero-voltage start-up, adjustable time relay, and audible/visual alarms give you precise control over every test cycle.

Built to IEC 60060 and GB/T standards, it serves power utilities, equipment manufacturers, railways, and research labs that need dependable withstand voltage testing at higher voltage levels.

 

Key Technical Advantages

 

5kVA / 100kV / 50mA - higher voltage, same compact form

Covers insulation tests on equipment rated up to 100kV - transformers, CTs/PTs, insulators, switchgear, and high-voltage cables. Same bench-top footprint as the 50kV model.

Zero-voltage start with time relay

Output ramps from zero every cycle - no residual voltage. Set exact test duration; audible and visual alarms signal completion or fault.

One unit, broad coverage

100kV output handles power transformers, CTs/PTs, bushings, insulators, switchgear, and high-voltage cables that require higher test voltages

Rugged, simple, low maintenance

Built to IEC 60060 and GB/T standards. Straightforward controls, robust construction, easy to maintain in the field.

 

Product Parameter 

 

Parameter Specification
Model MEYDQ-W5kVA-100kV
Rated Capacity 5kVA
Input Voltage 220V, single-phase
Input Current 22.7A
Output Voltage 0–250V (low-voltage side)
Output Current 25A
High Voltage Output 0–100kV
High Voltage Current 50mA
Instrument Voltage 100V
Frequency 50Hz
Start Method Zero-voltage start
Timing Control Adjustable time relay with audible/visual alarm
Cooling Method Natural air cooling
Standards IEC 60060, GB/T 16927.1

 

Actual configuration and performance should be confirmed according to the specific test object and testing requirements.

 

Application

 

product-530-470

The 5kVA 100kV AC Hipot Test Set is widely used across industries:

Power Utilities - Routine AC withstand voltage testing of transformers, CTs/PTs, insulators, and switchgear rated up to 100kV

Electrical Equipment Manufacturers - Factory acceptance testing (FAT) and type testing of high-voltage products

Metallurgical & Mining - Insulation testing of motors, generators, and high-voltage switchgear in industrial settings

Railway Systems - Testing traction equipment and railway power supply components

Research Institutions & Universities - High-voltage lab testing, teaching, and R&D

Power Cable Manufacturers - Insulation strength testing of medium and high-voltage cables

 

FAQ

 

Q1: What equipment can this 5kVA 100kV test set test?

A: It covers most routine AC hipot tests on equipment rated up to 100kV, including power transformers, CTs/PTs, cables, insulators, bushings, switchgear, motors, and generators. If your test object exceeds 100kV or requires higher capacity, we offer larger models (10kVA, 15kVA, etc.) in the same product line.

Q2: What standards does this test set comply with?

A: The system is designed and tested in accordance with IEC 60060 (high-voltage test techniques) and GB/T 16927.1 (general test requirements). Type test reports and factory test reports are available upon request.

Q3: Can the output voltage be adjusted?

A: Yes. The output voltage is continuously adjustable from 0 to 100kV via the control panel. The low-voltage input side outputs 0–250V, which is stepped up by the test transformer to the required high-voltage output.

Q4: Does the unit include safety features?

A: Yes. Key safety features include zero-voltage start-up (output always ramps from zero), adjustable time relay for precise test duration, audible and visual alarms for test completion and fault indication, and overvoltage/overcurrent protection. The control panel is designed for safe operator interaction at low voltage.

Q5: Can the product be customized?

A: Yes. We offer customization for input voltage (e.g., 110V/60Hz for North American markets), output voltage ranges, rated capacity, and special configurations. Contact us with your requirements and our engineering team will recommend the appropriate model.

Q6: How is the product shipped and what is the lead time?

A: We arrange shipment within 15 business days after order confirmation. Shipping method depends on the order quantity and equipment size. For urgent projects, please contact us to discuss expedited delivery options.

 

Request a Quote for the 5kVA 100kV AC Hipot Test Set

 

Need a specific configuration, single-line wiring diagram, or budget quote for the MEYDQ-W5kVA-100kV AC Hipot Test Set?

 

Send us your requirements:

  • Test object type
  • Required test voltage
  • Test frequency (50Hz/60Hz)
  • Input power supply available
  • Applicable standard
  • Quantity needed

 

Our engineering team will review your requirements and respond within 24 hours.

Request a Quote →

Hot Tags: 5kva 100kv ac hipot test set, China 5kva 100kv ac hipot test set manufacturers, factory, 10kVA 50kV Power Frequency Withstand Voltage Device, 10kVA 100kV AC Hipot Test Set, 15kVA 100kV AC Hipot Test Set, ac hipot test set, Power Frequency Withstand Voltage Device, 5kVA 100kV AC Hipot Test Set