5kVA 50kV AC Hipot Test Set

Send Inquiry
5kVA 50kV AC Hipot Test Set
Details
5kVA / 50kV / 100mA — Covers most routine hipot tests
Zero-Voltage Start — Safe ramp-up every cycle
Time Relay + Alarms — Precise test duration control
Compact Bench-Top — Small footprint, easy to move
CE Certified — Meets international safety standards
Single-Phase 220V Input — Runs on standard power
Wide Applications — Transformers, cables, insulators, switchgear
Low Maintenance — Rugged design for long-term use
Category
AC Hipot Test Set
Share to
Description
5kVA 50kV AC Hipot Test Set

5kVA 50kV AC Hipot Test Set

 

Moen's MEYD-W5kVA-50kV AC Hipot Test Set is a compact, bench-top high-voltage test solution designed for routine insulation strength testing in laboratories, manufacturing QC, and field service environments.

Rated at 5kVA / 50kV / 100mA, this test set covers the majority of everyday AC hipot testing needs - power transformers, cables, insulators, switchgear, motors, and other electrical equipment up to 50kV. Zero-voltage start-up, adjustable time relay, and audible/visual alarms give you precise control over every test cycle.

Built to IEC 60060 and GB/T standards, it's a workhorse for power utilities, equipment manufacturers, metallurgical plants, railways, and research labs that need dependable withstand voltage testing without the bulk and cost of a full resonant test system.

 

Key Technical Advantages

 

5kVA / 50kV / 100mA - bench-top size, no generator needed

Covers routine hipot tests on transformers, cables, insulators, and switchgear. Fits on a workbench or in a mobile test cabinet.

Zero-voltage start with time relay

Output ramps from zero every cycle - no residual voltage. Set exact test duration; audible and visual alarms signal completion or fault.

One unit, broad coverage

50kV output handles power transformers, CTs/PTs, cables, insulators, bushings, switchgear, and motors.

Rugged, simple, low maintenance

Built to IEC 60060 and GB/T standards. Straightforward controls, robust construction, easy to maintain in the field.

 

 

Product Parameter

 

Parameter Specification
Model MEYD-W5kVA-50kV
Rated Capacity 5kVA
Input Voltage 220V, single-phase
Input Current 13.63A
Output Voltage 0–250V (low-voltage side)
Output Current 13.63A
High Voltage Output 0–50kV
High Voltage Current 100mA
Instrument Voltage 100V
Frequency 50Hz
Start Method Zero-voltage start
Timing Control Adjustable time relay with audible/visual alarm
Cooling Method Natural air cooling
Standards IEC 60060, GB/T 16927.1

 

Actual configuration and performance should be confirmed according to the specific test object and testing requirements.

 

 50kV AC Hipot Test Set
Application

The 5kVA 50kV AC Hipot Test Set is widely used across industries:

Power Utilities - Routine AC withstand voltage testing of transformers, CTs/PTs, insulators, and switchgear

Electrical Equipment Manufacturers - Factory acceptance testing (FAT) and type testing of high-voltage products

Metallurgical & Mining - Insulation testing of motors, generators, and high-voltage switchgear in industrial settings

Railway Systems - Testing traction equipment and railway power supply components

Research Institutions & Universities - High-voltage lab testing, teaching, and R&D

Power Cable Manufacturers - Insulation strength testing of medium and high-voltage cables

 

 

 

FAQ

 

Q1: What equipment can this 5kVA 100kV test set test?

A: It covers most routine AC hipot tests on equipment rated up to 100kV, including power transformers, CTs/PTs, cables, insulators, bushings, switchgear, motors, and generators. If your test object exceeds 100kV or requires higher capacity, we offer larger models (10kVA, 15kVA, etc.) in the same product line.

Q2: What standards does this test set comply with?

A: The system is designed and tested in accordance with IEC 60060 (high-voltage test techniques) and GB/T 16927.1 (general test requirements). Type test reports and factory test reports are available upon request.

Q3: Can the output voltage be adjusted?

A: Yes. The output voltage is continuously adjustable from 0 to 100kV via the control panel. The low-voltage input side outputs 0–250V, which is stepped up by the test transformer to the required high-voltage output.

Q4: Does the unit include safety features?

A: Yes. Key safety features include zero-voltage start-up (output always ramps from zero), adjustable time relay for precise test duration, audible and visual alarms for test completion and fault indication, and overvoltage/overcurrent protection. The control panel is designed for safe operator interaction at low voltage.

Q5: Can the product be customized?

A: Yes. We offer customization for input voltage (e.g., 110V/60Hz for North American markets), output voltage ranges, rated capacity, and special configurations. Contact us with your requirements and our engineering team will recommend the appropriate model.

Q6: How is the product shipped and what is the lead time?

A: We arrange shipment within 15 business days after order confirmation. Shipping method depends on the order quantity and equipment size. For urgent projects, please contact us to discuss expedited delivery options.

 

 

Request a Quote for the 5kVA 50kV AC Hipot Test Set

 

Need a specific configuration, single-line wiring diagram, or budget quote for the MEYD-W5kVA-50kV AC Hipot Test Set?

 

Send us your requirements:

  • Test object type
  • Required test voltage
  • Test frequency (50Hz/60Hz)
  • Input power supply available
  • Applicable standard
  • Quantity needed

 

Our engineering team will review your requirements and respond within 24 hours.

Request a Quote →

Hot Tags: 5kva 50kv ac hipot test set, China 5kva 50kv ac hipot test set manufacturers, factory, 10kVA 50kV Power Frequency Withstand Voltage Device, 10kVA 100kV AC Hipot Test Set, 15kVA 100kV AC Hipot Test Set, ac hipot test set, Power Frequency Withstand Voltage Device, 5kVA 100kV AC Hipot Test Set

Send Inquiry