Integrated Cable Detector
This high-end, multi-functional pipeline detection equipment integrates multi-mode detection, precise identification, fault location, and GPS mapping. It boasts strong anti-interference capabilities and convenient operation .
Suitable for underground pipeline detection, cable identification, and fault diagnosis in municipal, power, and other fields, meeting the needs of the entire pipeline operation and maintenance process.
Product Introduction
MOEORW-W9008F2 The cable path detector is a multi-functional instrument for identifying and detecting cable paths. It features multiple functions including pipeline path detection, cable identification, pipeline grounding fault location, GPS mapping, and remote control . The instrument consists of a transmitter, transmitting current clamp, receiver , receiving flexible current clamp, connecting test leads, stethoscope, A-frame (optional), and mapping app (optional) .
Pipeline Path Detection: This instrument enables trenchless detection of metal pipelines and underground cables, facilitating pipeline surveys and depth measurements. Utilizing various filter technologies, it possesses strong anti-interference capabilities, enabling precise positioning and depth measurement. Suitable for detecting and inspecting various underground metal and non-metal pipelines, pipeline management and maintenance, municipal planning and construction, and power supply departments, it is an essential instrument for pipeline maintenance units. This function is achieved through the coordinated operation of a signal transmitter, receiver, signal transmitting clamp, and connecting test leads.
Product Parameter (specification)
1. Receiver Specifications
|
Function |
Pipeline detection (cable location tracking, direction display, depth measurement, current measurement), cable identification, grounding fault location, Bluetooth communication, cloud services. |
|
power supply |
7.4V DC 3400mAh rechargeable lithium battery |
|
Input method |
Built-in receiving coil; external flexible clamp; external A-frame |
|
Receive frequency |
Active detection frequencies: 577Hz, 640Hz, 1280Hz, 2.56kHz, 3.20kHz, 4.09kHz, 8.19kHz, 10kHz, 33kHz, 66kHz, 82kHz, 201kHz (among which the four frequencies of 640Hz, 1280Hz, 2.56kHz, and 3.20kHz are directional, and the receiver can identify the direction of the signal). Power frequency passive detection frequencies: 50Hz, 60Hz |
|
Pipeline detection mode |
Wide peak method, narrow peak method, and valley method |
|
Pipeline detection shows |
Classic positioning mode, full-screen signal mode, signal curve mode |
|
Pipeline detection Detection range |
Direct connection method: Generally, the cable length can be 0-30 kilometers, mainly determined by the grounding resistance, cable resistance, and cable burial depth. Coupling method: Generally, it can achieve cable lengths of 0-10 kilometers, mainly determined by grounding resistance, cable resistance, and cable burial depth. Induction method: Suitable for cables buried at a depth of less than 2m. |
|
Depth accuracy |
Precise planar positioning accuracy: Centerline position of the target cable or pipeline: ±5% (burial depth 0-3m) ±15% (burial depth 3m-20m) |
|
sound indication |
Frequency modulation tone that varies with signal strength |
|
Bluetooth communication |
It supports Bluetooth communication for instrument control and connection to a mobile app for various data processing. |
|
Network communication |
Built-in 4G network enables remote control function |
|
Interference distance |
When using coupling and induction methods, the transmitter will generate interference at close range. The distance of the interference is related to the transmission power and frequency. The higher the power and the higher the frequency, the stronger the interference. The minimum distance between the receiver and transmitter often needs to be determined experimentally. Pipeline detection: Coupling method can confirm no interference beyond 5m, induction method beyond 20m. Cable identification: Coupling method can confirm no interference at a distance of 5m. |
|
Cable identification |
Identification method: Intelligent identification using flexible calipers; The number of cables that can be specified is 1 to 10. Calibration value: A current percentage between the received signal and the transmitted signal that is between 75% and 135% of the calibration value is one of the conditions for successful identification; Directionality: The transmitting clamp, receiving clamp, and the loaded signal must be aligned in direction; this is one of the conditions for successful identification. |
|
Cable identification Detection range |
Direct connection method: can identify signals with a loop resistance of 0Ω to 8kΩ (generally applicable to cable lengths of 0-20 kilometers, mainly determined by grounding resistance and cable resistance). Coupling method: can identify signals with a loop resistance of 0Ω to 1kΩ; (generally applicable to cable lengths of 0-10 kilometers, mainly determined by grounding resistance and cable resistance) |
|
liquid crystal |
4.3-inch color LCD screen, supports touch screen operation |
|
satellite positioning |
Built-in GPS |
|
size |
Approximately 311mm*133mm*750mm |
|
quality |
Approximately 1.90 kg |
|
charger |
DC8.4V, 1A |
|
Connection interface |
1 USB port (for firmware upgrades and charging mobile phones) 1*SIM card slot (for IoT SIM cards) 1*DC charging port 1*Type-C charging port 1* Flexible clamp connection socket |
|
Flexible Current Clamp |
Approximately 620mm in length and 8mm in diameter. |
|
Inner diameter of flexible coil |
φ200mm |
|
Data storage |
It can store 1024 sets of data (data saving and satellite positioning functions must be enabled first). |
|
Operating temperature and humidity |
-10℃~40℃; below 80%Rh |
|
Storage temperature and humidity |
-10℃~50℃, ≤95%RH, no condensation |
|
Pressure resistance |
AC2000V/rms (before the front and rear ends of the casing) |
|
Suitable for safety regulations |
IEC61010-1 CAT III 600V, IEC61010-031, IEC61326, Pollution Degree 2 |
2. Transmitter Specifications
|
Function |
Multiple frequency signal transmission methods for pipeline path detection, cable identification, and fault location |
|
power supply |
11.1V DC 12800mAh rechargeable lithium battery |
|
Output method |
Direct output, inductive method, caliper coupling |
|
Output frequency |
128Hz, 512Hz, 577Hz, 640Hz, 1024Hz, 1280Hz, 2.56kHz, 3.20kHz, 4.09kHz, 8.19kHz, 9.80kHz, 10kHz, 33kHz, 66kHz, 82kHz, 83.1kHz, 133kHz, 201kHz |
|
Output power |
15W Max, 15 adjustable levels, fully automatic real-time impedance matching |
|
Direct-connected output voltage |
150Vpp MAX |
|
Circuit protection |
It has overload and short circuit protection |
|
Remote control |
The receiver can control the transmitter's parameters and output via a 4G network. |
|
liquid crystal |
5.6-inch capacitive touch LCD screen |
|
Instrument Dimensions |
Approximately 259mm x 211mm x 105mm |
|
quality |
Transmitter 3.00kg; Launch clamp 1.12kg |
|
charger |
DC 12.6V, 1A |
|
Launcher size |
250mm x 140mm x 35mm (Length x Width x Thickness) |
|
Launch clamp inner diameter |
φ150mm |
|
Launch clamp length |
3m |
|
Direct connection test cable |
3m |
|
Connection interface |
1 USB port (for firmware upgrades and charging mobile phones) 1*SIM card slot 1*Type-C charging port 1*DC charging port 1* Signal transmitting clamp and DC test lead connector |
|
Pressure resistance |
AC 3700V/rms (between the top and bottom surfaces of the instrument case) |
|
Electromagnetic properties |
IEC61326(EMC) |
|
Suitable for safety regulations |
IEC61010-1 (CAT III 300V, CAT IV 150V, pollution level 2) |
3. Optional features
|
Fault location |
When used with an A-frame, it can enable precise location of cable grounding faults. |
|
Cable identification |
Cable identification function can be achieved when used with a flexible coil. |
|
Surveying APP |
Using an app in conjunction with a receiver, this system enables GPS-based pipeline mapping, allowing users to locate, measure, manage, and view underground pipelines' geographic coordinates, depth, and other information. It also provides cloud services for data storage, backup, and transfer. |
|
stethoscope |
Can replace flexible coils for cable identification |
Product features and applications
- Multiple detection modes: classic positioning mode, full-screen signal mode, signal curve mode, and tracer probe mode.
- Classic positioning mode: Compass, direction and signal amplitude display, intuitively showing the left and right direction of the pipeline.
- Full-screen signal mode: 360° omnidirectional pipeline path indication, continuously displaying depth, current, and relative pipeline position. The interface is simple and intuitive, requiring no prior experience to operate.
- Signal curve mode: Displays historical signal strength curves, allowing you to locate cables by observing changes in the curves.
- GPS mapping function: Users can view the geographical coordinates of underground pipelines mapped by the receiver through the map in the mobile APP, and can see the burial direction of underground cables by observing the underground pipeline route guide map.
- It can store 1024 sets of detection and positioning data.
- The receiver has a 3.5-inch color LCD screen, and the transmitter has a 5.6-inch color capacitive touch LCD screen.
- Current direction determination (at some frequencies) can eliminate interference from adjacent lines and prevent tracking errors by calibrating the current direction.
- The color of the pipeline simulation line displays the signal interference intensity in real time.
- With a built-in frequency sweep test function, users can select a suitable signal frequency for pipeline measurement based on the frequency sweep results, avoiding interference from the same frequency.
- Fully digital high-precision sampling processing: stable and reliable, ultra-high sensitivity, extremely narrow receiving bandwidth, strong anti-interference capability, and can effectively suppress power frequency and harmonic interference from nearby operating cables and pipelines.
- Multiple detection frequencies: 12 active detection frequencies and 2 passive detection frequencies.
- The transmitter offers multiple signal output methods: direct output, clamp coupling, and induction.
- The transmitter features digital power amplification for high-power output, fully automatic impedance matching, and fully automatic protection.
Cloud service (optional) : Built on the Android platform (compatible with HarmonyOS), it uses the powerful computing performance and network communication capabilities of mobile phones to interact with the server in real time, enabling functions such as engineering measurement, task management, data management, data viewing, test report generation, data import, data export, and operation video.
Remote control function : The transmitter connects to the network via an external 4G network card. Users can remotely control the transmitter's signal output, changing the transmission frequency and power via a mobile app. This facilitates measurement and saves operation time.
Surveying App (Optional) : This is a self-developed app that integrates comprehensive information management functions such as recording, managing, and generating reports for measurement data. It is used in conjunction with a cable comprehensive detector to achieve satellite positioning surveying capabilities. The app can manage tasks and generate reports for engineers' pipeline inspection missions, featuring a user-friendly engineering wizard function and ease of use. It generates task reports with one click, including information such as length, depth, measurement frequency, measurement current, and location information, greatly improving the work efficiency of buried pipeline inspection personnel.
Cable Identification: Designed to solve the technical problems of cable identification for power cable engineers and cable workers. It can identify live cables and de-energized cables. Users can accurately identify a target cable from multiple cables using the instrument, avoiding serious accidents caused by accidentally cutting live cables. During cable identification, 10 cables can be pre-marked at the transmitting end before being identified at the remote receiving end, greatly saving the time of engineers traveling back and forth and improving work efficiency. Successful cable identification is marked with a √, and non-target cables are marked with an ×, enabling fast and automatic identification of target cables. This function is achieved through the cooperation of a signal transmitter, receiver, signal transmitting clamp, connecting test leads, and flexible clamps.
Signal transmitter : Used for pipeline path detection and cable identification. This device can apply identification signals to target cables through direct output, clamp coupling, induction, etc., with 12 different pulse signals available. The maximum signal output power is 15W, adjustable in 15 levels. This adapts to different application environments, making pipeline detection and cable identification more accurate and reliable. The instrument has a built-in high-power rechargeable lithium battery, automatic impedance matching, and fully automatic protection. The main unit features a 5.6-inch color capacitive touchscreen LCD display, showing real-time dynamic signal output status and battery usage.
Transmitter clamp : Suitable for clamp coupling method. The transmitter clamp couples the signal emitted by the transmitter to the target cable. The clamp jaw size is Φ150mm . The transmitter clamp is directional, and the transmitted signal flows in from the direction indicated by the arrow on the transmitter clamp.
Receiver : Used for pipeline path detection and cable identification signal reception. It features multiple built-in shielded 3D antennas, enabling effective identification of 12 different pulse-code current signals generated by the transmitter. It can also identify 50Hz and 60Hz power frequency signals. A 3.5- inch color LCD screen provides real-time dynamic display of 360° omnidirectional pipeline path indication, depth, current, and relative pipeline position .
A-frame (optional) : An A-shaped voltage signal sensor specifically designed for locating grounding faults in buried cables. The A-frame's two probes or probe discs accurately receive step voltage signals transmitted from a transmitter. After data analysis at the receiver, the grounding fault point can be precisely located. The probes or probe discs are independently interchangeable ; the probes are suitable for muddy surfaces, while the probe discs are suitable for concrete surfaces where direct insertion into the ground is not possible. The A-frame's lead wires are designed with aviation sockets, allowing connection to the receiver via aviation plug cables. It is easily detachable and compatible with an independently designed handle, enabling the A-frame to function independently for other purposes.
Flexible current clamp : Used for cable identification. This current clamp uses a Rockwell coil and has excellent transient tracking capability, enabling rapid identification of pulse-coded currents generated by the transmitter. It is suitable for thick cables or irregularly shaped conductors. Its jaws have an inner diameter of 200 mm, allowing for non-contact measurement without disconnecting the circuit under test, ensuring safety and speed.
Stethoscope: Used for cable identification. Similar in shape to a mouse, it quickly senses and identifies current signals in transmitters or cables. Its curved sensor design ensures a perfect fit against the cable surface. When used with the transmitter and receiver of this product, it can perform most of the functions of a flexible current clamp, and can replace it for cable identification in most situations. Simply place the stethoscope firmly against the cable being tested along its direction. Suitable for situations where it is inconvenient to use a flexible current clamp.
Special Note: When identifying de-energized cables, it is strictly forbidden to connect them to live cables. Live cable identification is only applicable to three-core armored cables. During identification, the transmitting clamp and receiving clamp must not be used interchangeably, and the direction of the input signal must be consistent.
Prodection details
Underground pipeline detection and survey
It is applicable to municipal, power supply, gas, and water supply departments to conduct trenchless path detection and burial depth measurement of underground metal/non-metal pipelines, power cables, communication cables, and gas/water pipes, and to complete pipeline surveys and file establishment.
01
Power cable identification and maintenance
During the construction and maintenance of cables in the power industry, the system can accurately identify the target cable (including live/de-energized cables) from multiple cables to avoid accidental sawing that could cause safety accidents. It can also be used for cable inspection to identify potential hazards in the cable laying process.
02
Pipeline grounding fault location
For issues such as damaged protective layers of insulated pipes, grounding faults in low-voltage cables, and sheath faults in high-voltage cables (mainly ultra-high-voltage single-core cables), this system enables precise location of fault points, providing accurate location references for pipeline maintenance.
03
Pre-construction exploration
Before excavation for building, road, and municipal engineering projects, a regional pipeline survey should be conducted in the construction area to identify the distribution of unknown underground pipelines, avoid damage to pipelines during construction, and ensure construction safety and normal pipeline operation.
04
Pipeline mapping and data management
When used with the optional surveying app, it enables GPS satellite positioning and geographic coordinate recording of underground pipelines, draws pipeline route maps, generates professional test reports, supports data storage, export, and cloud service interaction, and is suitable for scenarios such as pipeline information management and project acceptance.
05
Company Qualifications
Q: Are you a factory or a trading company?
We are a professional manufacturer of testing equipment.
Q: How is the after-sales service?
A: The warranty period is 12 months. After the warranty period, we also provide lifetime service paidrepair or service.
Q: How is the after-sales service?
A: The warranty period is 12 months. After the warranty period, we also provide lifetime service paidrepair or service.
Q: What about transportation?
A: It depends on your requirements. We can ship to your airport by air, to your seaport by sea, or to your office by courier.
We also accept cooperation with your shipping agent.
Q: Are your keyboard, interface, software, and manuals in English?
A: Yes, if you are using the English version of the keyboard, interface, software, and manual and require other languages, please contact us for confirmation.
Hot Tags: integrated cable detector, China integrated cable detector manufacturers, factory, cable fault locating system, Cable Fault Location Intelligent Bridge, Cable Sheath Fault Locator, Line Parameter Tester, Overhead Line Fault Location Instrument, Phase Detector