Multi-Channel Temperature And Humidity Scanner

Send Inquiry
Multi-Channel Temperature And Humidity Scanner
Details
The MOEORW-W690 automates inspection, calculation, and data logging to save time, reduce errors, and pass calibration easily. It delivers high-precision measurements compliant with official metrology standards, automatically computes uniformity, fluctuation, and deviation, and supports one-click U-disk export. Intuitive touch operation and stable performance help you improve efficiency, ensure quality, and simplify certification.
Category
Transformer Test Set
Share to
Description

Product Introduction

 

MOEORW-W690 is a multi-channel temperature & humidity inspection instrument for automatic cyclic detection and recording of temperature & humidity field distribution and variation. It complies with JJF1101-2003 (environmental test equipment calibration) and JJF1376-2012 (box-type resistance furnace calibration), supporting automatic calculation of fluctuation, uniformity, deviation and other performance parameters. It is widely used for verification and calibration of various temperature & humidity equipment, providing reliable testing, analysis and management tools for production, scientific research and metrology.

 

Product Parameter (specification)

 

Electrical Parameters

Measurement channel

20 RTD channels / 40 thermocouple channels + 8 humidity channels

Sampling speed

up to 0.1s per channel

Power supply

12V adapter / built-in rechargeable lithium battery

Dimensions

420×140×265mm; Weight:3.7KG

Operating environment

0–45℃, 0–80%RH (non-condensing)

Preheating time

30 minutes before use

Temperature & Humidity Index

RTD (Pt100/Pt10/Cu100/Cu50)

-200℃ to 800℃; accuracy ±(0.01%RD+0.05)℃

Thermocouple (S/R/B/K/N/E/J/T)

wide range up to 1820℃; accuracy class matching standard

Humidity (Rotronic probe)

0–100%RH; accuracy ±0.8%RH; resolution 0.01%RH

 

Product Feature

 

  • 32-bit ADC, high precision & high resolution
  • Support 4 RTD types and 8 thermocouple types
  • 3-wire / 4-wire RTD measurement to eliminate lead error
  • Multiple cold junction compensation modes for thermocouple
  • 7-inch capacitive touch screen, full touch operation
  • Auto-save inspection results, store up to 100 files
  • Support 5-channel curve display simultaneously
  • Auto-calculate fluctuation, uniformity, deviation
  • Support U-disk data export (XLS) and system upgrade
  • Compatible with upper computer for certificate generation

 

Product Application

 

  • Drying oven, incubator, constant temperature & humidity chamber
  • Climate aging test chamber, mold test chamber, salt spray test chamber
  • Corrosive gas test chamber, high & low temperature test chamber
  • Alternating humidity & heat test chamber
  • Box-type resistance furnace and other temperature & humidity equipment

 

Company Qualifications

 

 

FAQ

 

Q: How to connect sensors correctly?

A: ●RTD: 2 red wires to pin 1/3, 2 black wires to pin 2/4 (7-core socket)
●Thermocouple: positive to pin 1/3, negative to pin 2/4
●Humidity: connect Rotronic probe to 3-core socket as per pin definition

Q: Why is measurement inaccurate?

A: ●Insufficient preheating (at least 30 minutes)

●Calibration cycle too short (recommend ≥ total enabled channels × 1s)
●Unused channels not closed; sensor or wiring fault
●No periodic calibration (recommend calibration once per year)

Q: How to export inspection data?

A: Insert U-disk → enter File Record → select file → Data Export; system auto-saves to TEMPHUMI/HISTORY/date/FILExx.xls

Q: Can humidity be measured for resistance furnace?

A: No. When device type is set to box-type resistance furnace, humidity channels are forced disabled.

Q: How to set the center point for resistance furnace?

A: Enter data analysis → Center Point Setting; select any enabled channel as the center point (default: smallest channel number).

 

Hot Tags: multi-channel temperature and humidity scanner, China multi-channel temperature and humidity scanner manufacturers, factory