SF6 Gas Decomposition Product Tester

Send Inquiry
SF6 Gas Decomposition Product Tester
Details
MOEORW-WQZ41 The SF6 gas decomposition product detector is a modular precision testing device specifically designed for detecting the insulating gas properties of SF6 electrical equipment.
Equipped with anti-interference, dynamic temperature correction and pump pressure clearance systems, it provides accurate detection, fast response, and data storage and export capabilities.
It is widely used in SF6 gas detection scenarios in industries such as power, chemical, metallurgy, steel, and gas.
Category
SF6 Gas Analyzer
Share to
Description

Product Introduction

 

MOEORW-WQZ41 The SF6 gas decomposition product detector is specifically designed for testing the insulating gas properties of SF6 in electrical equipment. It is a modularly designed testing device; with the appropriate testing modules, it can be used to determine the decomposition products of SF6 gas. The instrument employs a combination of anti-cross-interference design, a pump-pressurized gas chamber sample gas purging system , dynamic temperature correction compensation technology, and error correction technology for different types of carrier gases to ensure testing accuracy. SF6 gas is introduced into the sensor at a specific flow rate, and the instrument directly measures the content of the main decomposition products of SF6 gas .

 

After the instrument completes its power-on self-test, the user can connect it to the device under test and adjust the gas inlet flow rate to directly obtain accurate SF6 gas decomposition product content. All test data will be stored in the instrument's memory and can also be uploaded to a computer after the test is completed.

 

Product Parameter (specification)

 

Sf6 Gas Decomposition Product Detection Module

Measurement range

[SO₂ ] 0~100 µl /l , [ H₂S ] 0~100 µ l/l , [HF] 0~10 µl /l , [CO] 0~500 µ l/l

Accuracy

SO₂ , H₂S , HF: Measured value ≤ 10 When the concentration is µ l/l , ±0.5; for measured values ≥10 At µ l/l , ±5%

CO: ±2.0 when the measured value is ≤50 µl /l; ±2.0 when the measured value is ≥50 µl/l. At µ l/l, ±4%

Repeatability

SO₂ , H₂S : Measured value ≤ 10 When µ l/l , ±0.2 µ l/l ; Measured value ≥10 At µ l/l , ±2%

CO: ±1.5 when the measured value is ≤50 µl /l. µl /l ; Measured value ≥50 At µ l/l , ±3%

HF: ±2%

Resolution

SO₂ , H₂S , HF, CO : 0.1 µ l/l

Response time

≤60s

 

Volumetric Weight

Dimensions 414333177mm
Weight Approximately 2.5 kg

 

Product features and applications

 

SF6 gas decomposition product detection module

Dynamic temperature correction and compensation technology

Variations in sample gas temperature and ambient temperature can affect the characteristics (baseline and range) of the electrochemical sensor, thus impacting measurement accuracy. This device incorporates a built-in sensor temperature characteristic curve and acquires sample gas and ambient temperatures in real time via an independent temperature measurement circuit. The measurement results are dynamically corrected based on the sensor temperature characteristic curve to ensure accurate and reliable measurements.

 

Anti-cross interference design

When using multiple electrochemical sensors to simultaneously measure a mixture of various target gases, cross-interference with a particular gas by one sensor can affect detection accuracy. A built-in specific chemical filter removes interfering gases before they reach the sensing electrodes of the electrochemical sensor, thus reducing interference from specific gases.

 

Pump-type gas chamber sample gas removal system

Gas measurement chambers typically employ a tubular structure design. Because the pressure inside and outside the chamber is the same, the discharge of sample gas from the chamber relies on the natural permeation between the sample gas and the outside air. This results in slow and incomplete removal of residual sample gas, affecting the accuracy of subsequent measurements. Furthermore, residual sample gas in the chamber shortens the sensor's lifespan. To address this, after each measurement, a pump can be used to draw outside air into the device. This air is then filtered, dried, and introduced into the chamber, creating a pressure difference that expels the sample gas from the chamber. This ensures no sample gas residue remains, maximizing measurement accuracy and extending the sensor's lifespan.

 

Prodection details

 

The MOEORW-WQZ41 SF6 gas decomposition product detector can be widely used in the power, chemical, metallurgical, steel, and gas industries to measure various indicators of gases.

 

Company Qualifications

 

 

FAQ

 

Q: Are you a factory or a trading company?

A: We are a professional manufacturer of testing equipment.

Q: How is the after-sales service?

A: The warranty period is 12 months. After the warranty period, we also provide lifetime service paidrepair or service.

Q: How is the after-sales service?

A: The warranty period is 12 months. After the warranty period, we also provide lifetime service paidrepair or service.

Q: What about transportation?

A: It depends on your requirements. We can ship to your airport by air, to your seaport by sea, or to your office by courier.
We also accept cooperation with your shipping agent.

Q: Are your keyboard, interface, software, and manuals in English?

A: Yes, if you are using the English version of the keyboard, interface, software, and manual and require other languages, please contact us for confirmation.

 

Hot Tags: sf6 gas decomposition product tester, China sf6 gas decomposition product tester manufacturers, factory, SF6 Dew Point And Purity Tester, SF6 Gas Comprehensive Analyzer, SF6 Gas Quantitative Leak Detector, SF6 Das Qualitative Leak Detector, SF6 Gas Dew Point Tester, Fully Automatic SF6 Density Relay Calibrator

Send Inquiry