Transformer Oil Gas Analyzer DGA
Product Introduction
Our company, committed to technological innovation, dedicated to industry analysis, and focused on chromatography R&D, proudly introduces the new MOEORW-W6970A Gas Chromatograph. This instrument features reliable performance, compact design, strong expandability, simple operation, and easy maintenance. Tailored for applications such as online analysis in university laboratories, petrochemical processing, and environmental monitoring, it offers flexible customization solutions. It delivers exceptional analytical capabilities and operational performance, making it a truly high-performance gas chromatograph.
Product Parameter (specification)
|
● Operation Display |
7-inch high-definition capacitive touchscreen; |
|
● Temperature Control Zones |
8 channels; |
|
● Temperature Range |
Ambient +5°C to 450°C, Increments;0.1°C, Accuracy;±0.1°C; |
|
● Programmed Temperature Steps |
16 steps (expandable to 99 steps); |
|
● Maximum Heating Rate |
80°C/min; |
|
● Gas Path Control |
Precision mechanical valve flow control; |
|
● External Events |
8 channels; Auxiliary control outputs;2 channels; |
|
● Injector Types |
Packed column injection, capillary injection, six-port valve gas injection, autosampler; |
|
● Detector Quantity |
4 (maximum); Selectable from FID, TCD, ECD, FPD, PDHID, PED, and NPD; |
|
● Injection initiation |
Manual or automatic selectable; |
|
● Communication interface |
Ethernet;IEEE802.3; |
|
1.3.2 Detector Technical Specifications 1. Hydrogen Flame Ionization Detector (FID) |
|
|
● Detection limit |
≤3.0×10⁻¹² g/s (hexadecane/isooctane) |
|
● Baseline noise |
≤2×10⁻¹⁴ A |
|
● Baseline drift |
≤1×10⁻¹³ A/30 min |
|
● Linear range |
≥10⁷ |
|
2. Thermal Conductivity Detector (TCD) |
|
|
● Sensitivity |
S ≥ 10,000 mV•ml/mg (benzene/toluene) (with selectable amplification;1×, 2×, 3×, 4×) |
|
● Baseline noise |
≤20 μV |
|
● Baseline drift |
≤30 μV/30 min |
|
● Linear range |
≥10⁵ |
|
3. Electron Capture Detector (ECD) |
|
|
● Detection limit |
≤1×10⁻¹⁴ g/mL (α-hexachlorocyclohexane-isooctane solution) |
|
● Baseline noise |
≤0.03 mV |
|
● Baseline drift |
≤0.2 mV/30 min |
|
● Linear range |
10⁵ |
|
● Radioactive source |
⁶³Ni |
|
4. Flame Photometric Detector (FPD) |
|
|
● Detection limit |
(S) ≤2×10⁻¹¹ g/s,(P) ≤1×10⁻¹² g/s; (Methyl parathion-anhydrous ethanol solution) |
|
● Baseline noise |
≤3×10⁻¹³ A |
|
● Baseline drift |
≤2×10⁻¹² A/30 min |
|
● Linear range |
Sulfur ≥10³; Phosphorus ≥10⁴ |
|
5. Nitrogen-Phosphorus Detector (NPD) |
|
|
● Detection limit |
(N) ≤1×10⁻¹² g/s (azobenzene)(P) ≤ 1×10⁻¹² g/s; (Malathion) |
|
● Baseline noise |
≤5×10⁻¹³ A |
|
● Baseline drift |
≤2×10⁻¹² A/30 min |
|
● Linear range |
For nitrogen ≥10², For phosphorus ≥10³ |
Product feature and application
★ Features technologically advanced 100Mbps/1Gbps Ethernet communication interfaces with built-in IP protocol stacks, enabling long-distance data transmission via corporate LANs and the internet. This facilitates laboratory setup, simplifies configuration, and streamlines analytical data management.
★ The dedicated workstation supports simultaneous connection of multiple chromatographs for data processing and instrument reverse control, simplifying documentation management.
★ The instrument can connect to the manufacturer via the internet for remote diagnostics and updates (requires user configuration).
★ Features a 7-inch high-definition capacitive touchscreen display.
★ Employs a multi-processor parallel operation mode for enhanced stability and reliability. Offers optional high-performance detectors such as FID, TCD, ECD, FPD, and NPD, with support for up to four detectors installed simultaneously to meet complex sample analysis demands.
★ Modular structural design simplifies future maintenance.
★ New microprocessor-based temperature control system delivers high precision, superior reliability, and excellent interference resistance. Features eight fully independent temperature control outputs supporting 16-step programmed temperature ramping (expandable to 99 steps). Equipped with an automatic column oven rear door system, enhancing near-ambient temperature control capability and accelerating heating/cooling rates.
★ The chromatograph incorporates a low-noise, high-resolution 24-bit AD circuit with baseline storage and subtraction capabilities.
★ The standard workstation is compatible with WinXP, Win2000, Win7, Win8, and Win10 operating systems.
★ The chromatograph's microcomputer system, featuring fully independent intellectual property rights, supports the MODBUS/TCP standard protocol for integration with DCS systems.
Prodection details
The Transformer Oil Chromatography Online Monitoring System is suitable for various oil-filled electrical equipment such as power transformers, reactors, and instrument transformers. It is widely applied in power plants, substations, transmission lines, metallurgical and chemical industries, and rail transit sectors. This system enables real-time monitoring of dissolved gas content in equipment insulation oil, provides early warnings for internal faults, and ensures the safe and stable operation of equipment.
Company Qualifications
Hot Tags: transformer oil gas analyzer dga, China transformer oil gas analyzer dga manufacturers, factory, Oil Acid Tester, Oil Filtration Machine, Oil Flash Point Tester, Oil Tension Tester, oil test equipment, Oil Trace Moisture Tester