Product Introduction
MOEORW-WGAS20 high current generator is a high-power integrated test equipment with 0–2000A stepless adjustable output, designed for large-current verification of high-capacity electrical equipment. It adopts high-power transformer design and 16-bit single-chip digital acquisition, providing stable current output and high-precision display. It can simultaneously show transformer ratio and polarity, suitable for large-scale busbar protection, high-current CT detection and heavy-load electrical tests.
Product Parameter (specification)
| Input Voltage | AC220V±10% |
| Rated Power | 10kVA |
| Output Current | AC 0–2000A Stepless Adjustable |
| Output Voltage | 5V |
| Measurement Accuracy | Class 0.2 |
| Current Stability | 0.2% |
| Output Waveform | Standard Sine Wave, Ripple<0.3% |
| Protection | Over-current, Over-voltage |
| Working System | 5 Minutes Short-time |
| Structure | Integrated |
| Environment Class | GB6587.1-86 Ⅲ |
Product Feature
- 0–2000A high-capacity output, strong driving capability
- Simultaneous display of current, ratio and polarity, one-step test
- High stability output, suitable for long-time test debugging
- Portable integrated structure, easy for on-site high-current test
- Dual over-current and over-voltage protection, safe for heavy load
- Good heat dissipation design, suitable for industrial harsh environment
- Compatible with various CT and busbar protection test
Product Application
- High-current busbar protection calibration
- Large-ratio current transformer test
- High-power electrical equipment temperature rise test
- Heavy-duty circuit breaker and switchgear verification
- Industrial and mining enterprise high-current on-site test
- Power system type test and factory inspection
FAQ
Q: Can it do impulse test?
A: Yes, set current → stop → power on again to complete impulse test.
Q: How to ensure test accuracy?
A: Keep current regulator at zero before power on; calibrate display regularly.
Q: Maintenance in long-term storage?
A: Avoid direct sunlight; turn on for 2 hours monthly to dehumidify.
Q: Wiring requirement for 2000A output?
A: Use sufficient cross-section copper wire at 10A/mm².
Q: Is grounding mandatory
A: Must be reliably grounded; connect ground wire first before operation.
Hot Tags: 2000a high power high current generator, China 2000a high power high current generator manufacturers, factory, 5000A Fully Automatic Temperature Rise And High Current Test Device, Single Phase Digital High Current Generator, Fully Automatic Temperature Rise Test Device, high current generator, Primary Current Injection Test Set, Temperature Rise High Current Generator