Temperature Rise High Current Generator

Send Inquiry
Temperature Rise High Current Generator
Details
The MEDL-W3000A High-Current Temperature Rise Tester is a fully automated testing device that uses a dedicated control board and touchscreen for operation. It is capable of supporting multi-module experiments with both manual and automatic switching, includes a large-screen data display and export functionality, and provides stable performance with an easy-to-use operation.
Category
High Current Generator
Share to
Description

Temperature Rise High Current Generator

 

Product Introduction

 

MEDL-W3000A High-Current Temperature Rise Tester employs a dedicated system control board for operation, utilizing the Vylon series touchscreen as the human-machine interface to achieve fully automated high-current testing. This series supports various high-current outputs, temperature measurements, and transformer ratio tests by installing different modules. Through the HMI, users can select manual or automatic operation, view temperature data, and perform basic data processing. Data export functionality can be added, enabling transfer of data to a computer via USB drive for further processing.

 

Product Parameter (specification)

 

Rated Capacity (Common Parameters)

40KVA*3

Input Current

AC 0 to 105.2A

Output Voltage

AC 0 to 12V

Output Current

AC 0 to 3000A*3

Voltage Measurement Accuracy

0.5% FS ± 3 digits

Current Measurement Accuracy

0.5% FS ± 3 digits

Timing Range

0 to 99999999S

Power Supply Voltage

AC 380V ±10%, 50Hz ±1 Hz

 

Product feature and application

 

● Large LCD display for current, time, status information, and prompts, providing clear and intuitive readings;

● Fully Chinese interface with simple, straightforward operation suitable for diverse applications;

● Touchscreen and conventional buttons for intuitive, quick, and easy-to-learn operation.

● Fully digital calibration method eliminates outdated potentiometer adjustments, offering exceptional field convenience and easy precision control;

● Status alerts and guided operation enable proficient handling even without manuals;

● Pause function allows halting current ramping/declining at any point during automatic control, with adjustable pause duration for convenient specimen observation;

● Automatic timing stops during experiment pauses and resumes upon pause termination. Resumes counting upon test continuation.

● Manual timing function: Manually initiates the timer during manual control.

● Manual control mode: Similar to traditional electric current adjustment, where buttons control current increase/decrease. The device automatically detects upper/lower limits and includes overcurrent protection. Entire test process is manually controlled and operated as needed.

● Transformer ratio testing function: Automatically calculates the current transformer ratio.

● Equipped with stop/emergency buttons for manual reset.

● Intelligent current ramping control: Slows ramping speed when approaching target current.

● Data export function: Stores device data to a computer via USB drive for further processing (select models).

● Immediate, accurate, and reliable protection during overcurrent or other faults;

● Combines hardware and software anti-interference technologies for stable performance and strong interference resistance, preventing abnormalities like system crashes, black screens, or distorted displays during testing.

 

Prodection details

 

 
 

Production and Factory Testing of Electrical Equipment (transformers, instrument transformers, busbars, bus ducts, connection terminals, power cables, etc.)

 
 
 

Operation, upkeep, and examination of electrical apparatus (inspections of power grid apparatus, maintenance of industrial power distribution systems)

 
 
 

Research, Development, and Performance Verification of Electrical Products (creation of new electrical devices, compliance certification testing of products)

 

 

Company Qualifications

 

 

FAQ

1)What is the output current range of the MEDL-W3000A High-Current Temperature Rise Tester?

Answer: The MEDL-3000A High-Current Temperature Rise Tester has an output current range of AC 0 to 3000A*3. It supports three-phase high-current output, meeting the high-current temperature rise testing requirements for various electrical equipment.

2)What control modes can the MEDL-W3000A High-Current Temperature Rise Tester switch between? How do you switch modes?

Answer: This device supports switching between automatic and manual control modes. To switch modes: On the high-current test interface, touch the "Auto" or "Manual" button. The pressed button will display orange, indicating the currently active mode. In automatic mode, the device automatically tracks and outputs current based on preset values. In manual mode, current for each phase or all three phases can be adjusted using the "Increase," "Decrease," "Increase All," and "Decrease All" buttons.

3)What are the possible causes and troubleshooting steps when the MEDL-W3000A High Current Temperature Rise Tester displays "No display upon startup"?

Answer: The fault causes and corresponding troubleshooting methods are as follows:
Possible cause: Power supply not connected.
Troubleshooting method: Connect the power supply promptly.
Possible cause: Internal fuse not properly installed or open circuit.
Troubleshooting method: Reinstall the fuse or replace it (note: use the same model fuse; do not substitute with other models).

 

Hot Tags: temperature rise high current generator, China temperature rise high current generator manufacturers, factory, Single Phase Digital High Current Generator, Primary Current Injection Test Set, Temperature Rise High Current Generator, Three Phase Digital High Current Generator, high current generator, 5000A Fully Automatic Temperature Rise And High Current Test Device

Send Inquiry