MOEORW-WHVA45 45kV VLF Hipot Tester with Tan Delta
Product Introduction
The MOEORW-WHVA45 VLF Hipot Tester 0~45kV can test medium-voltage cables according to relevant standards, including the European Committee for Electrotechnical Standardization (CENELEC) harmonized documents HD 620 S1:1996 and HD 621 S1:1996.
A 0.1Hz sinusoidal voltage with an effective value up to 24kV is available. This type of cable testing can detect faults in the insulation layer, especially water treeing damage, reliably preventing flashover not only in polyethylene (PE)/cross-linked polyethylene (XLPE) cables but also in paper-insulated cables. The testing procedure does not damage fault-free insulation. The cable can also be tested for insulation breakdown strength using DC voltage (positive and negative voltages) and trapezoidal AC voltage (rectangular wave voltage). The slewing rate of the rectangular wave voltage depends on the cable capacitance and is automatically adaptive. Additional leakage current measurements in DC mode allow for assessment of the relative quality of the cable insulation. The sinusoidal shape of the system test voltage can also directly test the cable's dielectric loss factor, thus determining the degree of loss factor degradation.
Product Parameter (specification)
The testing system is defined by the following technical parameters.
|
Output voltage |
||||
|
model |
MOEORW- WHVA34 |
MOEORW-WHVA45 |
||
|
Output voltage (sine wave) |
max. 24kV RMS (34kV PEAK ) |
max. 31.8kV RMS (45kV PEAK ) |
||
|
DC voltage |
±1–34kV |
±1–45kV |
||
|
resolution |
0.001kV |
0.001kV |
||
|
Accuracy |
1% |
1% |
||
|
Output current |
||||
|
Measurement range |
0–14mA |
0–14mA |
||
|
resolution |
1µA |
1µA |
||
|
Accuracy |
1% |
1% |
||
|
Maximum capacitive load |
0.1Hz@0.5µF/24kV rms /34kV peak 0.05Hz@1.0µF/24kV rms /34kV peak 0.01Hz@8.0µF/18kV rms /25kV peak |
0.1Hz@0.5µF/31.8kV rms /45kV peak 0.05Hz@1.0µF/31.8kV rms /45kV peak 0.01Hz@5.0µF/22kV rms /31kV peak |
||
|
Dielectric loss factor measurement |
||||
|
VLF-Sine |
1-24kV rms |
1-31.8kV rms |
||
|
Load range |
1nF-8uF |
1nF-5uF |
||
|
resolution |
1x10⁻⁵ |
1x10⁻⁵ |
||
|
Accuracy |
1x10⁻⁴ |
1x10⁻⁴ |
||
|
Measurement range |
1x10⁻⁴ -9999.9 x10⁻⁴ |
1x10⁻⁴ -9999.9 x10⁻⁴ |
||
|
tan-δ measurement frequency |
0.1Hz |
0.1Hz |
||
|
General information |
||||
|
Power consumption |
max.300VA |
max.400VA |
||
|
Reverse voltage protection |
13kV |
15kV |
||
|
Data Interface |
USB 2.0 |
|||
|
size (Width x Height x Depth) |
Peli Case 1430, 430 mm x 240 mm x 340 mm |
|||
|
weight |
22kg |
|||
|
Ambient temperature (run) |
-10 to +50 ° C |
|||
|
Storage temperature |
-20 to +60 ° C |
|||
|
Safety and Electromagnetic Compatibility (EMC) |
Compliant with CE standards and the Low Voltage Directive (2014/35/EC). Electromagnetic Compatibility Directive (2014/30/EC), Environmental Impact EN60068-2 and subsequent versions |
|||
|
User interface Provided in multiple languages |
English, Simplified Chinese, Russian, Spanish, etc. |
|||
Product feature and application
The MOEORW-WHVA45 test system integrates the following features and functions:
• Full AC voltage testing up to 24/31.8 kV RMS (sine wave voltage).
• Integrated machine for testing ultra-low frequency withstand voltage and dielectric loss factor
• Other output voltage waveforms for DC and rectangular waves
• Sheath testing and precise positioning, up to 10 kV
Leakage current measurement
• Manual and automatic frequency adjustment
• Voltage breakdown detection and automatic disconnection of high-voltage connection.
• Record the data to internal storage, then export it to a computer via USB drive to generate a test report.
• Firmware update via USB
Prodection details
Medium voltage cable insulation testing
For medium-voltage cables such as polyethylene (PE)/cross-linked polyethylene (XLPE) and paper insulation, insulation layer faults (such as water tree damage) are detected. The degree of insulation degradation is determined by ultra-low frequency withstand voltage and dielectric loss factor tests, and the tests do not damage fault-free insulation layers.
Comprehensive test of cable insulation performance
It can perform insulation breakdown strength tests on cables (positive and negative DC voltage, trapezoidal AC voltage mode), simultaneously measure leakage current, and evaluate the relative quality of cable insulation from multiple dimensions; it can also perform cable sheath testing and precise fault location (up to 10 kV).
Electrical equipment insulation testing
It can perform withstand voltage and dielectric loss tests on bushing-type electrical equipment, and is suitable for insulation performance testing needs of related equipment in power scenarios such as power plants.