Electrical measurement standard source
The MOEORW-W3067 electrical measurement standard source, also known as a multi-functional calibrator, is a high-precision AC/DC signal generator and a professional standard instrument for the calibration and verification of electrical measuring instruments.
It features a wide output range, high accuracy, strong stability, multiple adjustment modes, multiple automatic protections, and convenient operation.
Suitable for departments involved in instrument manufacturing, repair, and metrology verification, for calibrating various voltage, current, and resistance meters.
Product Introduction
The MOEORW-W3067 electrical measurement standard source (hereinafter referred to as the standard source) is an AC/DC standard voltage and current generator with a six-digit LCD display output value. It can be used for calibration, verification, and measurement of digital and pointer-type multimeters and various voltage and current meters of grade 0.2 and below. A standard resistor bank is also provided for convenient calibration of resistance meters.
The standard source employs a new type of composite high-power amplifier, offering high output power, high reliability, and low distortion. A superior 16-bit A/D converter chip significantly improves conversion speed and accuracy; the AC/DC converter uses a true RMS chip, ensuring accurate AC output and better linearity. The window simultaneously displays the actual output value, percentage, and frequency. Output adjustment can be performed either by bit or by percentage. The entire unit adopts a closed-loop control circuit design, greatly improving output stability. The unit also features automatic overvoltage and overcurrent protection.
This standard provides 22 AC/DC voltage output ranges (0~1000V); 22 AC/DC current output ranges (0~30A); 11×2 ranges of medium-value resistance (10Ω~20MΩ); and AC frequencies of 50Hz, 60Hz, and 400Hz (digitally synthesized, selectable via buttons). All these parameters and ranges are switched via precision switches. It features digital display, wide range, fine range division, high accuracy, good stability, and ease of use. It is widely used by instrument manufacturing, repair, and metrology verification departments.
Product Parameter (specification)
|
Output items |
Output range |
Rated output |
Maximum output |
Accuracy (20ºC±2ºC) |
|
pay straight flow electricity Pressure |
0~200 mV |
20mA |
100mA |
Basic error: DCV: ±(0.05% of reading + 0.02% of full scale) DCI: ±(0.05% of reading + 0.02% of full scale) ACV: ±(0.05% of reading + 0.02% of full scale) ACI: ± (0.05% of reading + 0.02% of full scale) Additional error at 400Hz: ±0.05% of reading Additional voltage error: ±0.02mV ACI < 1mA is not assessed. |
|
0~1V~2V |
50mA |
100 mA |
||
|
0~5V~10V~20V |
100mA |
200mA |
||
|
0~30V~100V~200V |
50mA |
100mA |
||
|
0~300V ~600V~1000V |
20mA |
40mA |
||
|
pay straight flow electricity flow |
0~100uA~500uA~2mA ~5mA~20mA~50mA ~200 mA~500 mA |
DC: 3V AC: 12V |
||
|
0~2A~5A |
DC: 3V AC: 12V |
|||
|
0~30A (20uA, 200uA, 2mA, 20mA, 200mA, 1A, 2A, 5A, 20A, 30A) |
1.5V |
±(0.05% of reading + 0.02% of range) |
||
|
Standard allow electricity Obstruction |
Indicated value |
power |
accuracy |
|
|
10Ω, 20Ω, 50Ω, 100Ω, 200Ω, 500Ω, 1kΩ, 2kΩ, 5kΩ, 10kΩ, 20kΩ, 50kΩ, 100kΩ, 200kΩ, 500kΩ, 1MΩ, 2MΩ, 5MΩ, 10MΩ, 20MΩ |
0.25W |
±(0.2%+20mΩ) |
||
|
For operating ambient temperatures exceeding 20℃±2℃, the additional error is less than the basic error for that range for every 10℃ change. The error for 30A 400Hz is ±(0.15% of the reading + 0.05% of the range). Output range: 0~120%RG Output power: For voltage ranges below 30V, the output current is ≤0.2A; for other ranges, the maximum is 25VA, and for current ranges of 200mA and below, the output voltage is 30V; for ranges of 1-30A, the maximum output is 30VA. |
||||
4.2: Stability: AC < 0.01%/1min of full scale; DC < 0.005%/5min of full scale.
4.3: Fineness adjustment: setting (0.002%)
4.4: AC distortion: <0.5%, 30A <2%
4.5: Output ripple content: <0.5%.
4.6: Output accuracy: <0.05%
4.7: External dimensions: 460×460×130 (mm)
4.8: Weight: Approximately 15 kg
Product features and applications
3.1 Automatic protection against voltage short circuit and current open circuit.
3.2 AC and DC current output can reach 36A.
3.3 Automatic overload protection and manual reset for more reliable operation.
3.4 Output adjustment can be done "by bit" or "by percentage".
3.5 Output adjustment can be achieved through external control coding or digital panel adjustment.
3.6 The whole machine adopts "closed-loop control" circuit design, which has high output accuracy and stability.
Prodection details
Instrument verification and calibration
It is used for calibrating, verifying, and measuring digital and pointer multimeters, as well as various voltage and current meters below grade 0.2. It can also be used to calibrate resistance meters with the help of built-in standard resistor groups.
Instrument manufacturing process
It provides instrument manufacturers with accurate AC and DC standard voltage/current signals as a benchmark for instrument debugging and testing during the production process, ensuring the accuracy of instruments leaving the factory.
Instrument repair field
When repairing various voltage, current, and resistance measuring instruments, standard electrical signals are provided to detect instrument faults, calibrate the measurement accuracy of the repaired instruments, and ensure that the performance of the repaired instruments meets the standards.
Metrology and testing department
As a standard instrument for metrological verification institutions, it provides a precise electrical signal source for the traceability and accuracy testing of various electrical measuring instruments, meeting the professional requirements of metrological verification.
Company Qualifications
Q: Are you a factory or a trading company?
We are a professional manufacturer of testing equipment.
Q: How is the after-sales service?
A: The warranty period is 12 months. After the warranty period, we also provide lifetime service paidrepair or service.
Q: How is the after-sales service?
A: The warranty period is 12 months. After the warranty period, we also provide lifetime service paidrepair or service.
Q: What about transportation?
A: It depends on your requirements. We can ship to your airport by air, to your seaport by sea, or to your office by courier.
We also accept cooperation with your shipping agent.
Q: Are your keyboard, interface, software, and manuals in English?
A: Yes, if you are using the English version of the keyboard, interface, software, and manual and require other languages, please contact us for confirmation.
Hot Tags: electrical measurement standard source, China electrical measurement standard source manufacturers, factory, Double Clamps Digital Phase Meter, Three phase clamp on phase voltmeter, Power Quality Analyzer, Meter Calibration Test Bench, Energy Meter Field Calibrator, Three Phase Energy Meter Test Bench